The submenu offers two scale/ div settings: 10dB and 5dB. Highlight the desired
one and press <Enter> to accept the change. After changing the scale to 5dB/div. it
might be necessary to adjust the reference level as well.
Markers
The analyzer has two markers available. Additionally the instrument shows the
difference in frequency and the level indicated by the two markers. That data is
available on the upper part of the display as Delta value.
To activate the marker, use the cursor keys or hit key 4 or 5 to highlight required
<Marker> field and press <ENTER>. Then select desired marker mode using the '^
and v' cursor keys.
Four marker modes are available.
39
Need help?
Do you have a question about the Quiver XT and is the answer not in the manual?