2.3.4. Program/Erase Time of Data Flash
Programming is performed in the unit of 4 bytes (1 word).
Erasing is performed in the unit of Page, Block, Area, or on entire chip. An erase time varies depending on the
command to be used. Please refer to "2.3.5 Memory Capacity and the Configuration" for detail.
2.3.5. Memory Capacity and the Configuration
Area
Capacity
(KB)
Size
(KB)
32
32
Note: The time above-mentioned is for reference only which calculated the Oscillation frequency of IHOSC1 on the
standard (10MHz<Typ.>). And indicate the case of the initial value of each register after reset. A data
transfer time is excluded.
2018-06-05
Table 2.14 Memory capacity and the configuration
Block
Size
pcs
pcs
(KB)
1
4
8
Programming
Page
time (Note)
Size
pcs
Word
(Bytes)
256
128
64.7µs
28 / 120
Flash Memory
Erasing time (Note)
Area
Page
Block
531ms
1.0ms
15.4ms
TXZ Family
Area
9.2ms
Rev. 2.0