Using Linearization Via The Quick Start Wizard - Siemens Sitrans LR250 Instruction Manual

Hart
Hide thumbs Also See for Sitrans LR250:
Table of Contents

Advertisement

Using Linearization via the Quick Start wizard

You can use the linearization feature to define a more complex vessel shape and enter up
to 32 level breakpoints where the corresponding volume is known. The values
corresponding to 100% and 0% levels must be entered. The breakpoints can be ordered
from top to bottom, or the reverse.
Example:
Level
Breakpoint
value
number
4
3
2
1
values are for example purposes only.
Note:
Open the menu Device – Quick Start:
1.
In Step 1 – Identification, press Next, to accept default values.
2.
In Step 2 – Application Type, select a volume application, for example Volume in a
vessel, and press Next.
3.
In Step 3 – Vessel Shape, choose the vessel shape option Linearization Table and
click on Linearization.
linearization
Page 42
SITRANS LR250 (HART) – INSTRUCTION MANUAL
Break-
Level
point
value
no.
(m)
19.5
1
0
2
5
9
3
9
5
4
19.5
0
Volume
0.5 m
value
(l)
0
500
20 m
3000
8000
7ML19985JE01