Siemens Sitrans LR250 Instruction Manual page 57

Hart
Hide thumbs Also See for Sitrans LR250:
Table of Contents

Advertisement

2.2.3. Volume Breakpoints
2.2.3.1. Maximum Volume
The maximum volume of the tank. Enter the vessel volume corresponding
to High Calibration Point. For example, if your maximum vessel volume is
8000 L, enter a value of 8000. The units of volume are not entered, but are
implied.
Values
Related Parameters
2.2.3.2. Dimension A
The height of the vessel bottom in sensor units when the bottom is conical,
pyramidal, parabolic, spherical, or flat -sloped. If the vessel is horizontal
with parabolic ends, the depth of the end. See 2.2.2.1. Vessel Shape for an
illustration.
Values
Related Parameters
7ML19985JE01
Vessel Shape
A
L
A
SITRANS LR250 (HART) – INSTRUCTION MANUAL
LCD DISPLAY/
Description
FLAT SLOPED BOT/
Flat sloped bottom
PARABOLIC ENDS/
Parabolic end horizontal
cylinder
LINEAR TABLE/
Linearization table
(level/volume breakpoints)
Range: 0.0000 to 99999
Default: 100.0
Low Calibration Point
High Calibration Point
Vessel Shape
Range: 0.0000 to 99999 mm
Default: 0.0
Vessel Shape
Also
required
(cont' d )
(cont' d )
maximum
volume,
dimension A
maximum
volume,
dimension A,
dimension L
maximum
volume, level
breakpoints,
volume
breakpoints