CHAPTER 3. Installing the system
3) With another extension cable, connect the 'Link2' port to the 'Link2' port.
4) With the third cable, connect the 'Link3' to the 'Link3'.
Caution for using expansion cabinet
Do not place the expansion cabinet directly on top of the basic cabinet. Doing so
may cause a system failure due to rising internal heat from the basic cabinet.
Caution for using extension cable
Check if extension cable is connected during operation. The expansion cabinet
may malfunction if extension cable is not connected during operation. In that
case, you should connect extension cable again and restart expansion cabinet.
Ensure that the EPM switches and IP address are correct as shown in section 2.4.
Incorrect setting may prevent the system from starting.
3-4
Figure 3.7 Connecting the basic cabinet to the expansion cabinet
© SAMSUNG Electronics Co., Ltd.