3.2 DIP-Switch Settings for 4405 Circuit Board

The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
Switch
Function
Primary 6500
Changes Gate
1
Opening
Direction
Secondary 6500
2
Changes Gate
Opening
Direction
Exit Loop Port
Output
3
Full Open Input
Auto-Close
4
Timer
Reverses Gate
5
External Shadow
Loop Detector
Single Operator
6
Dual Operators
Circuit
Board
7 and 8
Relay
Switch
Function
1
Gate Overlap
Magnetic lock
2
3
4
6500-065-J-7-18
SW 1 (Top 8 Switches)
Setting
Opens
Clockwise
Same as above, for secondary 6500 ONLY.
The output wired to terminal #4 becomes the output from the exit loop detector
OFF
plugged into the EXIT Loop port.
Normal Setting. Terminal #4 is a normal full open input.
ON
OFF
Auto-close timer is OFF. Manual input required to close gate.
ON
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
Normal Setting. Input to terminal #6 and reverse loop will stop and reverse gate to
OFF
the full open position during the close cycle ONLY.
Input to terminal #6 becomes a SHADOW loop input. It is only active when the gate
ON
is fully opened. (Shadow loop setting when external loop detector is used)
Normal Setting. Switch must be OFF for single operator.
OFF
Switch must be ON when primary/secondary (dual) gates are used.
ON
Normal Setting. Relay activates when gate is at open limit.
7-OFF
8-OFF
(Shadow loop setting when DoorKing Plug-In loop detector is used)
Relay activates when gate is not closed.
7-OFF
8-ON
Relay activates when gate is opening and open.
7-ON
8-OFF
Relay activates during opening and closing cycle.
7-ON
8-ON
See next page for switch definitions and typical settings.
SW 2 (Bottom 4 Switches)
Setting
Primary and secondary operators start at the same time (Normal setting for single
OFF
gate operator).
The secondary operator will start 1.5 sec. before primary operator during open
ON
cycle and the primary operator will start 1.5 sec. before the secondary operator
during the close cycle (Normal setting for bi-parting gate operators).
Normal Setting. Magnetic lock is not used.
OFF
Magnetic lock is used and connected to terminals 9 and 12. See page 27 for wiring.
ON
Normal Setting. Switch 3 MUST be turned OFF for Model 6500 operator.
OFF
Normal Setting. Switch 4 MUST be turned OFF for Model 6500 operator.
OFF
Description
ON
OFF
Description
Opens
Counter-Clockwise
21