Epmp 3000 Access Point Heater; Epmp 3000 Access Point Wind Loading - Cambium Networks ePMP 3000 Series User Manual

Hide thumbs Also See for ePMP 3000 Series:
Table of Contents

Advertisement

CHAPTER 2: SYSTEM HARDWARE
The ePMP 3000 connectorized module conforms to the specifications listed in
The connectorized module meets the low level static discharge specifications identified in
Electromagnetic compatibility (EMC) compliance
but does not provide lightning suppression.
Table 7 ePMP 3000 Access Point physical specifications
Category
Dimensions (Length x Width x
Height)
Weight
Table 8 ePMP 3000 Access Point environmental specifications
Category
Temperature
Wind loading
Humidity
Environmental

ePMP 3000 Access Point heater

At startup, if the ePMP 3000 Access Point module temperature is at or below 32° F (0° C), an internal
only activated when the unit is powered on and will not apply heat to the device once startup is
complete. When the unit temperature is greater than 32° F (0° C), the heater is deactivated and the unit
continues its startup sequence.
The effect on device startup time at various temperatures is defined in
Table 9 ePMP 3000 Access Point startup times based on ambient temperature
Initial Temperature
Startup time (from power on to operational)
-22° F (-30° C)
20 minutes
-4° F (-20° C)
6 minutes
14° F (-10° C)
2 minutes, 30 seconds

ePMP 3000 Access Point wind loading

on page
6-71
Specification
22.2 cm x 12.4 cm x 4.5 cm (8.75 in x 4.9 in x 1.75 in) without
brackets
0.7 kg (1.5 lbs) without brackets
Specification
-30°C (-22°F) to +55°C (131°F)
124 mph (200 kph) maximum. See
wind loading (Kg)
on page
95% condensing
IP55