2.9.1 DATALOGGER MODE

The [Datalogger Mode] option list allows you to disable Datalogger, transmit reports to an external
target via RS-232 port, or store selected data for later display. The default setting is [Off]. After enabling
the Datalogger, select a data format before generating a report.
To select a Datalogger Mode:
To access the [Datalogger Mode] option list press
Move the cursor to the desired mode by pressing
To store the selection press

2.9.2 DATALOGGER DATA

Set the Datalogger to record any or all of the data offered on the [Datalogger Data] option list shown on
next page. However, recording unneeded data wastes valuable system RAM. We recommend that you
always select [Site ID] (name) and [Time] to identify each line of data.
None
Site ID
Date
Time
Flow
Average Flow
Raw Flow
Total
Vs
Valc
Aeration
Alarms
Delta T (uSecs)
Temperature
Analog Inputs
*The Time field expands to HH.MM.SS when you select a logging interval of more than once per minute.
Siemens
Select datalogger destination
Datalogger Mode
Datalogger Data
Log Time Interval
Data Logger Events
Display Datalogger
Datalogger Setup
ENT
Default – Datalogging is disabled.
You entered this site name when you created the site.
The report date according to the meter's real time clock. (Format: MM.DD.YYYY)
The report time according to the meter's real time clock. (Format: HH.MM)*
The instantaneous flow measured at the time of the report.
The average flow rate measured since the last report.
The uncompensated flow rate in in
The total flow accumulation measured at the time of the report.
The average liquid sonic velocity since the last report.
The signal strength measured at the time of the report.
The aeration percentage recorded at the time of the report.
The letter codes of any alarms active at the time of the report (see below).
The Up to Down transit-time difference measured at the time of the report.
The instantaneous supply and return temperatures at the time for the report.
Any data appearing on an auxiliary input at the time of the report.
Dual Path
Path 1
Off
None
1 Min.
None
Off
3
/sec (only zeroed - no Reynolds number curve applied).
2-49
1010PFM-3G
Use this menu cell
to select a logging
interval.
Use this menu cell to
send Datalogger reports
to selected a destination
and pick a line wrap
mode.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans 1010aerwdp

Table of Contents