Section 3
3.1.10

USING 1012T MOUNTING TRACKS

The 1012TP and 1012THP Mounting Tracks provide a rigid mounting platform for Series 1011 universal
or high precision size A or B transducers. The mounting tracks service pipe sizes up to a maximum of
5.00" (140 mm) outer diameter. Operating temperatures are supported up to 250°F (121°C). The
assembly consists of lightweight aluminum track rails with integral transducer clamping screws. At-
tached index pins enable positive locating of the transducers at fixed spacing locations. Roller-chains
and tension screws secure the assembly to the pipe. The following instructions refer to 1011 universal
transducers. Please refer to Engineering Drawing 1012THP-7A for reflect mounting of high precision
transducers and 1012THP-7B for direct mounting of high precision transducers.
The 1012T mounting tracks support both Direct and Reflect mounting modes. The flow computer
recommends the appropriate transducers, mounting track and mounting mode, based on the pipe
data entries. Refer to the instructions in paragraph 2.4 for details on the Transducer Installation proce-
dure. If necessary, review paragraphs 3.1.2 through 3.1.4 for details on how to select and prepare a
mounting location on your pipe.

Installing a 1012T Mounting Track in Reflect Mode

Paragraph 2.4 describes the Transducer Installation procedures that lead up to the automatic selection
of transducers, mounting mode and spacing method. Examine the figure below, which shows a typical
Pick/Install Xdcr menu screen. Note the automatic assignment of model numbers for the transducer
and mounting track, plus the designation of the number index.
This example requires a Model 1012T Mounting Track to accommodate size B3 universal transducers.
Note the reported number index. You will be inserting an index pin into this hole on the track rail to
position one of the transducers (see diagram on next page).
1. Perform all required menu steps up until the point where you respond to the [Install Completed?]
prompt. Note the reported number index. You will be inserting index pins into this hole and the
reference hole on the track rail (see diagram on next page). Check to ensure that you have a
matched set of transducers. They both should have the same S/N number but marked with either
an "A" or "B" (e.g., 100A and 100B).
Siemens
2 Channel
Key [Install] after mounting transducers
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Empty Pipe Set
Zero Flow Adjust
Pick/Install Xdcr
3-16
[1]
SITE1
1011 Universal
B3
Reflect
Minimum
6
Track 1012TP
0.581
No
Channel Not Setup
Channel Not Setup
1010PFM-3G
Note selection of
type, size and
mounting mode.
Note selection of
mounting track part
number and number
index.