Troubleshooting - Intec FORCE 5150 Instruction Manual

Truck / trailer mount blowing machine
Table of Contents

Advertisement

TroubleShooting

Problem
HONDA GX390 does not start
Blower(s) does not run.
Agitator does not run.
T: 303-833-6644
Original Language - English
Likely Cause
Fuel switch in off position
Fuel not in gas tank
Emergency stop button has not
been pulled out.
Battery is dead.
HONDA is not running at full
throttle.
Auxiliary Blower's circuit
breaker needs to be in the 'on'
position.
Auxiliary Blower switch is OFF.
Hose may be disconnected
from one-way valve to blower.
Worn brushes in blower motor.
Blower has to be on for agitator
to come on.
Agitator circuit breaker needs
to be in the 'on' position.
800-666-1611
or
Instruction Manual
Remedy
Place lever in the ON position
by moving to the right towards
engine.
Refill gas tank with Premium
Unleaded gasoline.
Pull out emergency stop
bottom.
Charge or replace battery.
Move throttle to the full HIGH
position.
Place Auxiliary Blower's circuit
breaker in the 'on' position.
Place auxiliary blower switch
into the ON position.
Contact Intec for appropriate
troubleshooting.
Have a qualified technician
replace blower motor.
Turn blower on.
Place Agitator circuit breaker in
the 'on' position.
www.inteccorp.com
|
13