Step 2 –Remove filter from its cover. Please use caution as filter is thin; avoid tearing.
Step 3 - Clean filter -- shake, used compressed air, or wash with water. Re-install into system.
Wired Remote Cord
Ensure your wired remote cord is in good operating condition with the black jacket not worn and no
individual wires showing. If an individual wire is showing, or if wires were pulled from the transmitter's
jacket or male plug which inserts into the control panel, correct prior to use.
Airlock and Seals
The airlock assembly is one the most important items to keep in good condition. Foreign objects in the
airlock can cause damage and reduce the machine's production. Seal failure is the most common
airlock assembly failure. Seal failure prevents the airlock from holding the proper pressure. Seal
failure will reduce the machine's production. A machine with seal failure will have air blow out of the
airlock into the hopper, reducing the amount of air exiting the machine outlet. It is recommended to
visually inspected seals each week to ensure proper running condition. Replace airlock seals if a cut or
tear is evident. Airlock seals should be replaced every 300 hours of operation, or once per year. Visit
www.inteccorp.com or contact Intec for replacement instructions.
Chain
Clean and lubricate the chains once per year. Use a dry lubricant when lubricating the chain; do not
use oil as oil will attract foreign particles like dust to chain. If the machine is often used in dusty
conditions, then clean and lubricate the chain more frequently than once per year.
Belts
Belts will stretch over time. New belts will stretch relatively quickly and limited additional stretching
over use. The FORCE 5150's belts are properly tensioned when leaving the factory, yet stretching will
require you to re-tension the belts.
Generator: It is important for the generator to run at full operating speed (~3600 rpms); a slipping belt
will reduce the generator's speed which will not allow for proper operation of the system. To tighten
the generator's belt, simply loosen each of the four bolts holding the generator to the FORCE 5150's
frame, push the generator in the direction away from the HONDA motor to tension the belt. When the
belt has approximately ½" of play, then tighten the generator into place.