Intec FORCE 5150 Instruction Manual page 15

Truck / trailer mount blowing machine
Table of Contents

Advertisement

Problem
Machine is on, yet no material
comes out of hose.
Variable Speed is 'on' and
Variable Speed Setting is below
100%, yet still a lot of air flow.
Insulation exiting hose is
dribbling out.
Machine makes a banging noise
when agitator is operating.
T: 303-833-6644
Original Language - English
Likely Cause
Slide gate is closed.
Insulation blockage in hose.
Blower is off.
Air pocket in hopper is
preventing insulation from
feeding into agitators.
Airlock seal is worn.
Airlock has an obstruction
preventing insulation from
exiting.
Auxiliary blower is on.
Variable Speed Setting needs to
be decreased.
Heavy insulation material.
Kink in hose.
Airlock seal is worn.
Chain is loose.
800-666-1611
or
Instruction Manual
Remedy
Open slide gate.
Turn system off, remove hose
and clear blockage.
Turn blower on.
Shut HONDA, press in E-Stop.
Redistribute insulation material
inside hopper.
Inspect airlock seals for cuts
and wear. Have a qualified
technician replace airlock seals.
Shut HONDA, press E-stop in,
then remove obstruction.
Place the Auxiliary Blower
Circuit Breaker in the 'off'
position.
Reduce Variable Speed Setting
closer towards zero.
Push slide gate in 1-2 holes.
Turn up variable speed on
Primary Blower.
Turn variable speed selector
switch to 'off' to allow for
maximum power on Primary
Blower.
Turn on Auxiliary Blower.
Straighten hose.
Inspect airlock seals for cuts
and wear. Have a qualified
technician replace airlock seals.
Stop HONDA motor. Have a
qualified technician adjust chain
tensioner.
Adjust chain tensioner.
www.inteccorp.com
|
14