Quick Access Airlock Door: By removing six bolts, the Quick Access Airlock Door can be opened on its
hinge to enable quick change of the airlock seals to ensure appropriate air sealing and peak
production.
Set up and Operation

System Set-Up:

INITIAL OPERATION
During initial operation, install the fresh air inlet for the HONDA GX390.
A. Engine Fresh Air Inlet mounting plates: These mounting plates enable
you to connect the 10" hose provided with your system (and connected
to the HONDA engine) to a fresh, clean air source outside of your
vehicle. Recommendation is to:
a. Cut a 10" diameter hole into the side wall or floor of your truck /
trailer. NOTE: be sure to cut in a non-load bearing area.
b. Mount the Outside Plate (on the outside of the truck) and Inside
Plate (on the inside of the truck) – sandwiching the wall or floor -- with four nuts.
c. Hose Ring: The Hose Ring will mount to the Inside Plate.