Maintenance

Preventative maintenance will provide for many years of trouble-free use.
HONDA GX390
Please consult the HONDA manual for appropriate engine maintenance.
A few quick items related to the engine:
1. Initial oil change required after 20 hours of use
a. Recommend to use 5W-30 oil; consult manual for ideal oil in your operating region and
typical temperature ranges.
2. Clean engine air filter weekly.
3. Run engine at full throttle for appropriate operation of the FORCE 5150 blowing machine.
Cleaning
Clean the interior and exterior of the machine weekly by wiping with a rag and/or blowing with
compressed air; this will help maintain the longevity of the mechanical components in addition to the
system's finish. The machine has been designed to work in a dusty environment. However, without
periodic cleaning and maintenance, the performance of the machine will decline potentially leading to
failure.
Filters
Blower: Recommendations are to clean the blower inlet air filter at the beginning of each day. This
foam filter can be cleaned by simply taking out of its holder, shaking insulation and foreign materials
out of the filter, and then re-installing into its holder. Replacement filters are available at Intec.
Generator: Recommendation is to clean the generator air filter on a monthly frequency.
Step 1 – remove filter cover from generator
T: 303-833-6644