SERVICE PROGRAM MODE
Mode No.
5
(Class 1, 2, and 3)
816
Remote Service
1
I/F Setting
2
CE Call
3
Function Flag
6
Device Information
Call Display Setting
7
SSL Disable
8
RCG Connect Timeout
9
RCG Write Timeout
10
RCG Read Timeout
11
Port 80 Enable
821
Remote Service Address
1
CSS-PI device code
2
RCG IP Address
824
NV-RAM Data Upload
1
NV-RAM Data Upload
Function / [ Setting ]
Selects the remote service setting.
[0 ~ 2 / 2 / 1 /step]
• 0: Remote service off
• 1: CSS remote service on
• 2: NRS remote service on
Performs the CE Call at the start or end of the service.
[0 ~ 1 / 0 / 1 /step]
• 0: Start of the service
• 1: End of the service
This SP is activated only when SP 5816-001 is set to
"2".
Enables/disables the remote service function.
[0 ~ 1 / 0 / 1 /step]
• 0: Disabled
• 1: Enabled
Displays/does not display the device information call
content.
[0 ~ 1 / 0 / 1 /step]
• 0: Not displayed
• 1: Displayed
Uses/does not use the RCG certification by SSL when
calling the RCG.
[0 ~ 1 / 0 / 1 /step]
• 0: Uses the RCG certification
• 1: Does no use the RCG certification
Specifies the connect timeout interval when calling the
RCG.
[1 ~ 90 / 10 / 1 second/step]
Specifies the write timeout interval when calling the
RCG.
[0 ~ 100 / 60 / 1 second/step]
Specifies the read timeout interval when calling the
RCG.
[0 ~ 100 / 60 / 1 second/step]
Enables/disables the access via port 80 to the SOAP
(Simple Object Access Protocol) method.
[0 ~ 1 / 0 / 1 /step]
• 0: Disabled
• 1: Enabled
Selects the PI device code.
[0 ∼ 4 / 0 / 1 /step]
To validate the setting, turn off and on the main power
switch.
Sets the RCG IP address for calling the center.
Use this to copy NVRAM data from the machine to an
SD card.
5-38