Admissible nozzles;
Identifcation
FC 711 M
0005
1505
2505
4005
5005
6505
FC 1024 M / MP / TCA
00045
15045
25045
40045
50045
65045
5.3
Working pressures and spray flow rates
Infinite pressure and flow rate regulation by means of overflow safety valves. Set desired
operating stage on the handwheel of the overflow safety valve:
Working pressure
FC 711 M
115
90
70
50
FC 1024 M / MP / TCA
240
190
140
90
50
Jet shape
Angle
Full jet
Flat jet
15 °
Flat jet
25 °
Flat jet
40 °
Flat jet
50 °
Flat jet
65 °
Full jet
Flat jet
15 °
Flat jet
25 °
Flat jet
40 °
Flat jet
50 °
Flat jet
65 °
Flow rate
11,5
10,0
9,0
7,5
17,0
15,0
13,0
10,5
7,5
32
Flow rate
l/min
-
11,5
-
17,0
Working
Recoil
pressure
force
bar
N
115
20
240
48