Pitco Solstice Electric Fryers
Checking Resistance
Checking the Resistance of the Transformer
1.
Disconnect all electrical power. Remove the
front panel (see "Removing the Controller Front
Panel Bezel" on page 12), entrance box covers
(see "Removing the Entrance Box Covers" on
page 13), and entrance box wire guard (see
"Removing the Entrance Box Wire Guard" on
page 14).
2. Disconnect the secondary side terminals.
3. Connect the multimeter to the secondary
terminals and check the resistance.
Secondary Terminals
.7 ohms =+/- 20ohms
SE Series Service Manual
4. Disconnect the primary side terminals.
5. Connect the black lead of multimeter to the
primary terminal marked "5"and check the
resistance readings of taps in following chart on
page 18.
17