Checking Your New Fryer

Your new fryer has been carefully packed into one crate. Every effort has been made to ensure that your fryer is delivered
to you in perfect condition. As you unpack your new fryer, inspect each of the pieces for damage. If something is damaged,
DO NOT sign the bill of lading. Contact the shipper immediately, the shipper is only responsible for 15 days after delivery.
Check the packing list enclosed with your fryer to ensure that you have received all of the parts to the fryer. If you are
missing any parts, contact the dealer from whom the fryer was purchased.
To prevent equipment damage, don't tilt the fryer onto any two of it's casters or pull the unit by the fl ue vents.
Locate your Pitco Frialator warranty and fi ll in the serial number of the fryer and the date received. You will fi nd the serial
number on the plate inside the door. Put your warranty card in a safe place for future reference. DO NOT return the card to
Pitco Frialator.

Leg/Caster Installation and Adjustment

Installing the legs and leveling the fryer is done with a 7/16" wrench, socket, and a large pair of water pump pliers. The legs/
casters must be installed to provide the necessary height to meet sanitation requirements and assure adequate air supply
to the burner. Attach the legs by performing the following procedure:
a. Lay the fryer on its side being careful not to damage the fl ue by pulling on it. Protect the outside of the fryer
with cardboard or a drop cloth when laying it down.
b. Attach each leg/caster with the hex head cap screws supplied with the fryer. Each leg/caster requires four 1/4-
20 x 5/8" cap screws.
c. Mount the screws from the inside of the fryer with the nut on the outside. The nuts have lock washers attached
to them, therefore it is not necessary to use lock washers.
d. When all four legs/casters are mounted, stand the unit up being careful not to put too much weight on any one
leg/caster. Adjust the height and level the fryer by adjusting the leveling devices on the leg/caster with the water
pump pliers.
e. On units with casters, move the fryer to the desired location and lock the wheels using the locking devices on
the front of the casters.
The fryer must be properly restrained to prevent movement or tipping. This restraint must prevent the fryer from
movements that would splash hot liquids on personnel, which could cause severe burns or injuries.
Always wear oil proof gloves when moving or handling equipment or hot liquids.

Installation Clearances

The fryer needs clearance around it for proper operation. Adequate clearances allow for servicing and proper burner
operation. The clearances shown below are for cooker installation in combustible and noncombustible construction.
BACK
SIDES
FLOOR-Combustible
Counter top must be constructed of a non-combustible material for SG14C counter top fryer installations.

Gas Connection

Your fryer will give you peak performance when the gas supply line is of suffi cient size to provide the correct gas fl ow.
The gas line must be installed to meet the local building codes or National Fuel Gas Code ANSI Z223.1 Latest Edition. In
Canada, install the fryer in accordance with CAN/CGA-B149.1 or .2 and local codes. Gas line sizing requirements can be
determined by your local gas company by referring to National Fuel Gas Code, Appendix C, Table C-4 (natural gas) and
Table C-16 (propane). The gas line needs to be large enough to supply the necessary amount of fuel to all appliances
without losing pressure to any appliance.
NEVER supply the fryer with a gas that is not indicated on the data plate. Using the incorrect gas type will cause
improper operation. If you need to convert the fryer to another type of fuel, contact your dealer.
4
CAUTION
WARNING
Combustible Construction Non-Combustible Construction
6"
6"
9"
WARNING
L20-195 R7
0"
0"
9" (Needed for Combustion)