Diagram Identifying Terminals For Second Resistance; Checking The Resistance Of The Dvi Switch - Pitco Solstice SE Series Service Manual

Table of Contents

Advertisement

Pitco Solstice Electric Fryers 
 
 
Diagram Identifying Terminals for Second Resistance 
PP10429
Secondary Resistance
TAP
Volts
10 ‐ 6
24V
Primary   Resistance
Tap
Volts
5 ‐ 1
240V
 
5 ‐ 2
208V
5 ‐ 3
120V
 
 
Checking the Resistance of the DVI Switch 
1. Remove the DVI connection.
 
SE Series Service Manual 
Secondary Resistance
Resistance
TAP
0.7
10 ‐ 6
Primary   Resistance
Resistance
Tap
30.4
5 ‐ 1
25.3
5 ‐ 2
9.9
5 ‐ 3
18 
PP10428
Volts
Resistance
24V
0.6
Volts
Resistance
480V
119.5
440V
107.7
380V
90.2
2. Connect the multimeter to the DVI leads and
check the resistance.
DVI Resistance Table  
Valve Closed
Near Zero Ohm
Valve Open
Open Circuit