1.2.2

Software Support

Based on the EtherCAT standard, Advantech provides the necessary DLL drivers
and Windows utilities to configure the AMAX-4800 series modules, including I/O
modules integrated with Windows XP/7/8/10.
Advantech also provides a Common Motion I/O API for users to develop unique
applications under a Common Motion architecture in order to unify the user interfaces
of all Advantech motion devices.
Users can also configure parameter settings via a third-party EtherCAT master, such
as TwinCAT, Codesys, or Acontis, by using the AMAX-4800 series module's ESI file
to connect to existing EtherCAT networks.
1.3

Specifications

1.3.1

Communication

Item
Interface
Data Transfer Medium
Distance Between modules
Communication Cycle Time
Data Transfer Rates
1.3.2

General

Item
Connectors
Dimensions
Operating Temperature -20 ~ 60 °C (32 ~ 140 °F)
Storage Temperature
Storage Humidity
Power Supply
Certification
*N
AMAX
4817
N
2
Description
EtherCAT
Ethernet/EtherCAT cable (min. CAT5), shielded
Max. 100 m (100BASE-TX)
100 us
100 Mbps
Description
10-pin terminal block, 3.81 mm *N
3-pin screw terminal block, 3.81 mm * 2 (power)
RJ-45 * 2 (EtherCAT)
120 x 120 x 40 mm (4.72 x 4.72 x 1.57 in) for AMAX-4817/20/30/33/34/50/
60
168 x 120 x 40 mm (6.61 x 4.72 x 1.57 in) for AMAX-4855/56/62
-40 ~ 70 °C (-40 ~ 158 °F)
5 ~ 95% RH (non-condensing)
10 ~ 30 V
DC
CE, FCC Class A
AMAX
AMAX
AMAX
AMAX
4820
4830
4833
4834
1
4
4
4
AMAX
AMAX
AMAX
4850
4855
4856
4
8
8
7
AMAX-4800 User Manual
AMAX
AMAX
4860
4862
3
6