9.25. Command 203: Set DIP Switch Override
Request Data Bytes
Byte
Format
0
Unsigned-8
Response Data Bytes
Byte
Format
0
Unsigned-8
Command-specific Response Codes
Code
Class
0
Success
1-2
3
Error
4
5
Error
6-127
9.26. Command 204: Reset COPM Fault
Request Data Bytes
Byte
Format
None
N/A
Response Data Bytes
Byte
Format
None
N/A
Command-specific Response Codes
Code
Class
0
Success
1-15
16
Error
17-127
Description
0 = Setting from DIP switch
1 = Override DIP switch
Description
0 = Setting from DIP switch
1 = Override DIP switch
Description
No command-specific errors
Undefined
Passed parameter too large
Undefined
Too few data bytes received
Undefined
Description
N/A
Description
N/A
Description
No command-specific errors
Undefined
Access restricted
Undefined
FL500 HART® Communication Operating Manual
Device-specific Commands
US