Honeywell Apex Technical Handbook page 110

Gas detection system
Hide thumbs Also See for Apex:
Table of Contents

Advertisement

MAN0604_Issue 09_02-2013
2110M8030
APPENDIX A - SPECIFICATIONS
Size:
Weight:
Mountings:
Configuration
The Certified Junction Box can be configured during installation and operation to accept any of the
Certified Sensors it is compatible with (see the gas/cartridge tables in section A.2).
Certification and Approvals
Hazardous Area Certifications
ATEX:
UL:
CSA:
Junction Box certified to CSA 22.2 No. 152 only when certified sensor is fitted with specific
cartridges. See A.2 Cartridges, Flammable SG16 - US/Rest of the world version (page 108)
CE Marking
Complies with EU directives 2004/108/EC (Electromagnetic Compatibility).
Complies with EN 50270, EMC - Electrical Apparatus for the Detection and Measurement of Combustible
Gases, Toxic Gases or Oxygen
Complies with EU directive 94/9/EC (ATEX) for use in Hazardous Areas.
140mm wide x 95mm high x 152mm deep.
3000gm.
Provision for two M10 bolts, centres 68mm apart.
Approvals by Baseefa
II 2 G D Ex d IIC Ex tD A21 IP67
T100° (Tamb -40 to +55°C)
T135° (Tamb -40 to +80°C)
Certification Number: Baseefa08ATEX0253
Approvals by UL
Class I, Division 1, Groups B, C, D
T4° (Tamb -40 to +80°C)
T5° (Tamb -40 to +55°C)
Approvals by CSA
Class I, Division 1, Groups B, C, D
T4° (Tamb -40 to +75°C)
T5° (Tamb -40 to +55°C)