Troubleshooting - Adleepower AP2G3-337 Instruction Manual

General-purpose inverter
Hide thumbs Also See for AP2G3-337:
Table of Contents

Advertisement

10. TROUBLESHOOTING

Cause of fault message
Display symbol
Discharge LED
No display
extinguished
Power device failure
PF01
during acceleration
Power device failure
PF02
during constant
frequency operation
Power device failure
PF03
during deceleration
Power device failure
PF04
during stand-by
EEP1
EEPROM access error
EEPROM check-sum
EEP2
error
LOLO
Low voltage
UPLO
U.V.W. open
Communication loss or
LOSE
error
dcbr
DC braking mode
contents
Review the power system.
Check that MCCB has been
turned on or no poor contact.
The acceleration time is too short.
Boost voltage too high
Check the motor is locked or the
load is too heavy
Disconnecting the output wiring
U.V.W.
Restart (Run) the inverter check for
the same message
Check for sudden change in load
Check that the ambient
temperature is too high
The load GD
Power supply voltage is too high
Check around the noise source.
Power supply voltage is too high.
Rework with previous process.
Check for the same message.
Input voltage is too low.
The load is exessive.
Output U.V.W. open
This is normal
Check point
2
is excessive
84
Suggested remedy
Turned on or Replace MCCB
Increase the acceleration time
Reduce CD21 contents
Reduce the load factor
Repair
Eliminate sudden change in
load
Reduce the ambient
temperature
Set the deceleration time
2
suitable for load GD
Reduce th voltage within
specified range
Remove the cause
Reduce the voltage
Repair
Increase input voltage
Reduce the load
Check output U.V.W. circuit
or setting CD93=0
Check communication circuit
or communication code
Setting CD19

Advertisement

Table of Contents
loading

Table of Contents