Adleepower AP2G3-337 Instruction Manual page 36

General-purpose inverter
Hide thumbs Also See for AP2G3-337:
Table of Contents

Advertisement

Deceleration time 2
CD26
F
(HZ)
Acceleration
time 2
2CH=ON
Acceleration
time 1
2CH=OFF
To operate inverter with 2CH function, check to see CD42 or CD43=3.
2CH command inputs from FT1 or FT2 terminal.
Carrier frequency
CD27
Increase the carrier frequency would reduce motor noise but efficiency
might be decreased.
Reduce the carrier frequency would increase noise and reduce motor
current, than gain better efficiency.
Setting Range
Default Value
Deceleration time 1
2CH=OFF
Deceleration time 2
2CH=ON
Time(Sec)
AP2G3-337~375
AP4G3-337~3110
AP2G3-3110~3220
AP4G3-3150~3220
34
0.1 ~ 6000.0SEC
10.0SEC
Description
Acceleration time 1
Deceleration time 1
Acceleration time 2
Deceleration time 2
Setting Range 1.0~15.0K
Default Value
Setting Range 1.0~10.0K
Default Value
2CH
OFF
ON
15.0K
10.0K