First speed setting
CD00
Press
increment .
Press
key to select the digit for quick setting.
Press
to save the setting value.
ENTER
Parameter lock
CD01
0 : Lock 1 : Unlock
Function to prevent inadequate setting.
To change the contents data of CD , set CD01=1 and press
To lock the data set CD01=0 and press
Acceleration time 1
CD02
CD02 value corresponds to the
time of acceleration from 0 to 50/
60HZ.(For 120Hz. setting, the
arrival time to 120Hz is double.)
Setting Range
60HZ region
50HZ region
key for increase or decrease the speed with 1HZ
Setting Range
Default Value
Setting Range
Default Value
.
ENTER
F
60HZ
0.1
25
0.00 ~ 400.00HZ
60.00HZ
50.00HZ
0 or 1
0
first.
ENTER
0.1 ~ 6000.0Sec
10.0Sec
6000 TIME(Sec)