Adleepower AP2G3-337 Instruction Manual page 44

General-purpose inverter
Hide thumbs Also See for AP2G3-337:
Table of Contents

Advertisement

Dynamic braking
energy limit
CD51
The higher the percentage, the more braking energy.
The lower the percentage, the lower braking energy.
Description of regenerative discharge braking active period.
1.
0 ~ 100% Deceleration period
2. 101 ~ 200% Braking active period of
3. 201 ~ 300% Braking active period of
Remark : NO.1,2,3 are different working situations, but their braking
energy ranges are 0 ~ 100%.
Version selector
CD52
Select function CD52, then use UP/Down key to select F50.0/F60.0
Version. Press
setting and go into waiting mode..
S curve
CD53
Setting S curve non-Linear Accel/Decel Operation from 1 to 10.
Setting 0 is normal operation without S curve.
Setting Range
Default Value
(Decel/accel/constant frequency)
(Decel/accel/constant frequency/stand-by)
Setting Range
to save it. System will return to the factory
ENTER
Setting Range
Default Value
60HZ region
50HZ region
42
0 ~ 300%
100
F50.0/F60.0
F60.0
F50.0
0 ~ 10
0