Adleepower AP2G3-337 Instruction Manual page 74

General-purpose inverter
Hide thumbs Also See for AP2G3-337:
Table of Contents

Advertisement

Power on start lock
(External terminal
only)
CD80
CD80
(Run when power on)
CD12=1, operation switch="ON"
0
AC motor drive will run
CD12=1, operation switch="ON"
1
AC motor drive doesn't run
CD12=0, operation switch="ON"
2
AC motor drive will run
CD12=0, operation switch="ON"
3
AC motor drive doesn't run
MT output signal
selection
CD81
0 : Analog frequency meter. (Mix output is CD14's setting value)
1 : Analog current meter. (When CD82=100, MT mix. Output(10V) is
250% of rated AC motor drive current)
Note : 1V represent how mach current depend model.
Example : When CD82=100 & AP2G3-337 output 17A (rated AC motor
drive current), MT output 4V.
Setting Range
Default Value
Start lock
Setting Range
Default Value
Operation status when operation
command source is changed
CD12=1
CD12=1
Keep previous status
CD12=0
drive will run
CD12=0
drive doesn't run. operation switch
need "OFF" then "ON". AC motor
drive will run.
72
0 ~ 3
0
CD12=0, OPE7
CD12=0
CD12=1, AC motor
CD12=1, AC motor
0 or 1
0

Advertisement

Table of Contents
loading

Table of Contents