Adleepower AP2G3-337 Instruction Manual page 76

General-purpose inverter
Hide thumbs Also See for AP2G3-337:
Table of Contents

Advertisement

RUN terminal
CD91
ARR terminal
CD92
0 : RUN(CD46).
1 : ARR(CD55).
2 : Section ending signal : Terminal output 10ms long signal if each speed
is finished.
3 : Cycle ending signal : Terminal output 10ms long signal if each cycle is
finished.
U.V.W. open
protection
CD93
0 : Disable.
1 : Enable.
Note 1 : CD93=1, display "UPLO" when U.V.W. open.
Note 2 : If output current is less than 20% (output rated current) or op-
eration under circumstance of high frequency, we suggest cancel-
ling CD93.
Dead time
compensation
CD94
0 : Enable.
1 : Disable.
Setting Range
Default Value
Setting Range
Default Value
Setting Range
Default Value
Setting Range
Default Value
74
0 ~ 3
0
0 ~ 3
1
0 or 1
1
0 or 1
0