OPERATING IN WINTER (Ref. to Fig. 5)
To optimise carburettor function when operating in temperatures below 10°C we advise mixing
cold air with the hot air coming from the cylinder area so as to pre-heat the intake air. To do this
all that is required is to:
– Remove the cover and air fi lter (see § 6.1.1) placing the cover (C) in view.
– Loosen screw (X) and turn the position the inlet cap (C), tighten screw (X).
– On completion, replace the air fi lter and cover.
C
X
FIG. 5
5.1) Carburettor
The carburettor is factory set for optimum performance and adjustment should be avoided.
5.2) Adjust idling
In case of unstable running at idle speed, allow a short warm-up period then (Ref. to Fig. 6):
Remove the fi lter cover and adjust the screw (M) so the engine runs in a stable condition at mini-
mum revs. (2600 - 2800 rpm).
In idling position the transmission shaft must not turn.
M