EMC and immunity
EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests,
test acc. to:
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-4-9
EMC interference emission
EN 55022
FCC 47 CFR Part
15
German Lloyd
Stability
Vibration
Shock
a. Product code A: Approval = CE, UL
Product code B: Approval = CE, UL, GL, railway (along track), Sub Station, ATEX/IECEx
Produktcode H: Zulassung = CE, UL, GL, Bahn (along track), Sub Station
(See "Combination options of the device variants RS20/RS30/RS22/RS32" on page 23.
See
"Combination options for the RS40 device variants" on page
70
Electrostatic discharge
Contact discharge
Air discharge
Electromagnetic field
80 MHz ... 3000 MHz
Fast transients (burst)
Power line
Data line
Voltage surges
Power line, line / line
Power line, line / ground
Data line
Conducted disturbances
10 kHz - 150 kHz
150 kHz ... 80 MHz
Pulse magnetic fields
Class A
Class A
Classification + Construction Guidelines VI-
7-3 Part 1 Ed.2001
IEC 60068-2-6 Test FC test level according
to IEC 61131-2
Germanischer Lloyd Guidelines for the
Performance of Type Tests Part 1
IEC 870-2-2 table 3 normal installation
according to EN 61850-3
IEC 60068-2-27 Test Ea test level according
to IEC 61131-2
IEC 870-2-2 table 3 normal installation
according to EN 61850-3
a)
a)
A
B
H
4 kV
8 kV
8 kV
8 kV
15 kV
15 kV
10 V/m
20 V/m
20 V/m
2 kV
4 kV
4 kV
1 kV
4 kV
4 kV
0.5 kV
1 kV
1 kV
1 kV
2 kV
2 kV
1 kV
4 kV
4 kV
3 V
3 V
3 V
10 V
10 V
10 V
300 A/m 300 A/m
a)
a)
A
B
H
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
a
a)
A
B
H
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
26.)
Installation RS20/22/30/32/40