2.3

Installing an SFP transceiver (optional)

Use only Hirschmann SFP transceivers which are suitable for usage with the
device.
See "Accessories" on page 75.
Proceed as follows:
 Remove the protection cap from the SFP transceiver.
 Push the transceiver with the lock closed into the slot until it latches in.
2.4

Adjust DIP switch settings

The 2-pin DIP switch on the front panel of the device gives you the following
options:
RM
ON
Stand by
Figure 17: 2-pin DIP switch
Switch
Switch
RM
Stand-by
Position
Position
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Delivery state: both DIP switches "ON".
 Before starting operation of the device, check whether the default settings
of the DIP switch correspond to your requirements.
50
Ring
Coupli
Ring
redun
ng
manager
dancy
switch
an
an
aus
on
on
on
on
on
off
Coupli
Ring
Contro
ng
port
l port
manag
er
aus
1 + 2
off
1 + 2
on
1 + 2
3
Installation RS20/22/30/32/40
Coupl
Software
ing
configuratio
port
n
4
SW
configuration
has priority
over DIP
switch
configuration
Release 05 12/2015