Electric Diagram; Temperature Protection - Atlas Copco SF 15+ Instruction Book

Oil-free scroll compressors
Table of Contents

Advertisement

2.5

Electric diagram

The complete electrical diagram is available in the electric cubicle of the compressor. For
connection of the supply wires, please see section
2.6

Temperature protection

The compressor is equipped with an ambient temperature sensor. The sensor creates a warning
message on the controller if the ambient temperature rises above 40 °C (104 °F). If the ambient
temperature reaches 45 °C (113 °F), the compressor is stopped.
1
Automatic condensate drain outlet
2
Ambient temperature sensor
20
• The electrical installation must correspond to the applicable codes.
• The mains supply and earthing lines must be of suitable size. See section
cable size and
fuses.
• The installation must be earthed and protected by fuses in each phase.
• An isolating switch must be installed near the compressor. Make sure that this
switch is open to isolate the compressor from the mains before carrying out any
connection.
Condensate drain connections
Condensate drain connections on SFD
Electrical
connections.
3
Manual condensate drain valve
Instruction book
Electric
2920 7140 52