Installation proposal
Reference
1
2
Procedure
1. Install the compressor on a level floor, suitable for taking the weight of the compressor in a
frost free and preferably low dust location.
2. Compressed air outlet valve.
3. Delivery pipe.
The pressure drop over the air delivery pipe can be calculated as follows:
Δp = (L x 450 x Q
d = inner diameter of the pipe in mm
Δp = pressure drop in bar (recommended maximum: 0.1 bar (1.5 psi))
L = length of the pipe in m
P = absolute pressure at the compressor outlet in bar
2920 7140 52
Description
Minimum free area to be reserved for the compressor installation
Ventilation proposals
1.85
5
) / (d
x P), with
c
77