Pre-Installation

2 Pre-Installation
2
2

2.1.1 Receiving Inspection

Inspect the packaging and equipment closely when
received. Any indication of careless handling by the carrier
should be noted on the delivery receipt, especially if the
equipment will not be immediately uncrated. Obtain the
delivery person's signed agreement to any noted damages
for any future insurance claims. Ensure that the model
number and power match the order and intended use for
the drive.
NOTE
IMPORTANT LOST OR DAMAGED GOODS INSPECT THIS
SHIPMENT IMMEDIATELY UPON ARRIVAL
If goods are received short or in damaged condition, insist
on a notation of the loss or damage across the face of the
freight bill. Otherwise no claim can be enforced against
the transportation company. If concealed loss or damage is
discovered, notify your carrier at once and request an
inspection. This is absolutely necessary. Unless you do this
the carrier will not entertain any claim for loss or damage.
The agent will make an inspection and can grant a
concealed damage notation. If you give the transportation
company a clear receipt for equipment that has been
damaged or lost in transit, you do so at your own risk and
expense. Danfoss IS WILLING TO ASSIST YOU TO COLLECT
CLAIMS FOR LOSS OR DAMAGE, BUT WILLINGNESS ON
OUR PART DOES NOT MAKE US RESPONSIBLE FOR
COLLECTION OF CLAIMS OR REPLACEMENT OF MATERIAL.
THE ACTUAL FILING AND PROCESSING OF THE CLAIM IS
YOUR RESPONSIBILITY.
10
Option Panel Operating Instructions
Ensure that the model number and power match the order
and intended use of the drive.
Material No.: 174H2222
Drawings: 176U8989
Input Power: 480 VAC, 65.7 A, 3 Ø, 60 Hz
Motor: 460 VAC, 65 A
Short Circuit Rating: 5 kA rms sym. at rated input V max.
Envir. Rating: UL Type 1
Max. Ambient: 45 °C/ 113 °F
S301050T4E013CMM13XSXXZ1XGCXXXXXXXXXXXX0
See information packet for installation instructions.
Illustration 2.1 Sample Panel Label
1 Panel input rating
2 Panel output rating
3 Serial number
Table 2.1 Legend to Illustration 2.1
Ensure that the model number and power match the order
and intended use for the drive.

2.1.2 Pre-installation Check

1.
2.
3.
®
MG14I102 - VLT
is a registered Danfoss trademark
1
2
3
Danfoss Inc.
Milwaukee, WI 53224, U.S.A.
Tel.: +1 (800) 432-6367
Fax.: +1 (815) 639-8002
Serial No.: 018702Y097
Humidity: 95 % Non-Cond.
Compare option panel model number to what
was ordered.
Ensure each of following are rated for same
voltage:
Drive
Option panel
Power line
Motor
Ensure that panel output rating is equal to or
greater than motor total full load current for full
motor performance.
For multiple motor applications, add the
full load current ratings of all motors.
Motor power size and option panel
must match for proper overload
protection.
If panel rating is less than motor, full
motor output cannot be achieved.