F.3.3 Model 8032-27 and Load Cell Wiring
Connect the "common" VW- conductor from the load cell to the 8032-27 by lifting up on
the orange tab located on the opposite side of the six black conductors, inserting the
common conductor fully into the 8032-27 (Figure 34), and then pushing down on the
orange tab until it snaps into place. Refer to Table 16 to identify which conductor carries
the common VW- signal.
10 pin Bendix
Function
PT06A-12-10P
H
Common
White's black and Green wires are switched on Geokon 3 gauge VW load cells prior to serial number 3313.
*
Table 17 details the connections between the load cell and 8032-27 with the multiplexer
board.
Table 17 - Standard VW Load Cell Wiring When Using 8032-27
Figure 34 - Model 8032-27 Jumper Wire Assembly
3 Gauge VW Load
Cell, Purple Cable
White's Black*
Table 16 -Common Conductor Chart
Multiplexer
Vibrating Wire
Board
with Thermistor
1H
1L
2H
2L
S1
Shield Drain Wire
3H
3L
4H
4L
S2
5H
5L
6H
6L
S3
•
•
•
11H
11L
12H
12L
S6
4 Gauge VW Load
Cell, Purple Cable
Green
VW Sensor #1
8032-27
Thermistor
Thermistor
VW Sensor #2
8032-27
-
-
-
VW Sensor #3
8032-27
-
-
-
•
•
•
VW Sensor #6
8032-7
-
-
-
31
6 Gauge VW Load
Cell, Orange Cable
Blue