F.3.3 Model 8032-27 and Load Cell Wiring
Connect the "common" VW- conductor from the load cell to the 8032-27 by lifting up on
the orange tab located on the opposite side of the six black conductors, inserting the
common conductor fully into the 8032-27 (Figure 34), and then pushing down on the
orange tab until it snaps into place. Refer to Table 16 to identify which conductor carries
the common VW- signal.
10 pin Bendix
Function
PT06A-12-10P
H
Common
White's black and Green wires are switched on Geokon 3 gauge VW load cells prior to serial number 3313.
*
Table 17 details the connections between the load cell and 8032-27 with the multiplexer
board.
Table 17 - Standard VW Load Cell Wiring When Using 8032-27

Figure 34 - Model 8032-27 Jumper Wire Assembly

3 Gauge VW Load
Cell, Purple Cable
White's Black*
Table 16 -Common Conductor Chart
Multiplexer
Vibrating Wire
Board
with Thermistor
1H
1L
2H
2L
S1
Shield Drain Wire
3H
3L
4H
4L
S2
5H
5L
6H
6L
S3
11H
11L
12H
12L
S6
4 Gauge VW Load
Cell, Purple Cable
Green
VW Sensor #1
8032-27
Thermistor
Thermistor
VW Sensor #2
8032-27
-
-
-
VW Sensor #3
8032-27
-
-
-
VW Sensor #6
8032-7
-
-
-
31
6 Gauge VW Load
Cell, Orange Cable
Blue