Model 8032-27 And Load Cell Wiring - Geokon 8025 Instruction Manual

Multi-channel datalogger
Table of Contents

Advertisement

F.4 Model 8032-27 and Load Cell Wiring
Connect the "common" VW- conductor from the load cell to the 8032-27 by lifting up on the
orange tab located on the opposite side of the six black conductors, inserting the common
conductor fully into the 8032-27 (see picture), and then pushing down on the orange tab until it
snaps into place. Refer to the table below to identify which conductor carries the common VW-
signal.
10 pin Bendix
PT06A-12-10P
Function
H
Common
* White's black and Green wires are switched on Geokon three gage VW load cells prior to serial number 3313.
The following wiring chart details the connections between the load cell and 8032-27 with the
multiplexer board:
Model 8032-27 Jumper Wire Assembly
3 Gage VW Load Cell,
Purple Cable
White's Black*
Common Conductor Chart
Multiplexer
Board
1H
1L
2H
2L
S1
3H
3L
4H
4L
S2
5H
5L
6H
6L
S3
11H
11L
12H
12L
S6
Standard VW Load Cell Wiring When Using 8032-27
4 Gage VW Load Cell,
Purple Cable
Green
Vibrating Wire
with Thermistor
VW Sensor #1
8032-27
Thermistor
Thermistor
Shield Drain Wire
VW Sensor #2
8032-27
-
-
-
VW Sensor #3
8032-27
-
-
-
VW Sensor #6
8032-7
-
-
-
33
6 Gage VW Load Cell,
Orange Cable
Blue

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro-800

Table of Contents