Audio Configuration
Phone Connection
Interfacing with a VX system is configured in the Phone Connection section. Having each show profile with the option to
connect to either a different server or different studio adds flexibility.
The Phone Server IP field is for the IP address of the Telos VX product. The Studio Name field is a Studio Configuration defined
in the VX. The Show Name is optional, if declared, the VX Show will be made the active VX show. Some prefer to leave this field
empty and allow for VX show calls from another means.
The Phone Connection settings need to be in place in order to use Fixed or Selectable Phone types.
Monitor Section
The monitor section is divided into four columns for each of the monitoring points;
CR Monitor - the control room is where the surface resides
CR Headphone - the operator of the surface
Preview - the Preview (or cue) output
Studio Monitor - the external studio to the surface, commonly used as the talk studio.
There are nine rows of items that can be set;
Volume - set the volume to a defined value on show load or do not set (keep existing level)
Volume Adjust - allow the operator control of the volume (effectively a lock option)
Dim Gain - define the attenuation during a dim event. -inf is silence of the main content where 0 is no attenuation.
Gain in Muted State - to defeat the mute state common in radio, for example in TV applications.
Source - define the default source to load on show load.
Source sSelection - allow the operator control of source selection.