Omron V700-D23P41 User Manual page 18

For semi standard-compatible cidrw system
Hide thumbs Also See for V700-D23P41:
Table of Contents

Advertisement

Section 2
Unit Specifications
(2) ID port
Characteristic
Connector specification
Communication standard
Baud rate
Total cable length
(Pin arrangement)
1
6
Connection with link unit
Connect the CIDRW controller to the link unit using the cable whose configuration is specified below.
Limit the whole cable length to 15 m.
CIDRW
controller
D-SUB
9-pin
socket
#4-40
*1 Ground the shielded cable either on the CIDRW controller side or link unit side.
• Recommended cable: CO-MA-VV-SB 5PX28AWG (Hitachi Cable, Ltd.)
• Recommended connector: socket-Model XM2D-0901 (OMRON), hood-Model XM2S-0913
(OMRON)
Wrong wiring connection can lead to a malfunction of the equipment. Be fully sure of the correct
wiring connections.
V700-L21
16
User's Manual
9-pin D-SUB connector plug with #4-40UNC lock screws
RS-232C
9600, 19200, 38400 bps
(9600 bps is default; selectable in setup mode)
15 m max.
Pin No.
Signal name
1
2
Receive data
3
Send data
5
4
5
Signal ground
6
9
7
Request send
8
Clear to send
9
Symbol
Pin No.
1
RD
2
SD
3
4
SG
5
6
RS
7
CS
8
9
*1
Specification
Symbol
Direction
Input
Leave this pin OPEN.
RD
Input
SD
Output
Output
Normally OFF
SG
Input
Leave this pin OPEN.
RS
Output
CS
Input
For verifying established link
Input
Leave this pin OPEN.
Pin No.
Symbol
1
2
3
4
5
6
7
8
9
Comment
RD
Link unit
SD
D-SUB
9-pin
SG
socket
#4-40
RS
CS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V700-l21V700-hmd13 seriesV700-l11V700-hmd11-1V700-hmd13V700-hmd13a

Table of Contents