Input Check Designation (Normal); Sequential Numbering - SATO DR300 Operator's Manual

Sato barcode printer operator manual
Hide thumbs Also See for DR300:
Table of Contents

Advertisement

DR300 Operator Manual

Input check designation (Normal)

1 Normal, alphanumeric character
Digit
Designated
Position
18
Input check 1
19
Input check 2
20
Bold Font
21
Reserved

Sequential numbering

1 Normal, alphanumeric character
Digit
Designated Item
Position
22
Sequential function
23, 24
25, 26
27, 28,
Step (increase, decrease)
29
30, 31
Repeat quantity
32-39
Minimum data range
40-47
Maximum data range
* Sequential numbering is for numeric data only.
Item
0 : when online mode
0 : when online mode
0 : None
1 : Right
2 : Lower
3 : Right & Lower
0
Start Position
Data Count
Chapter 9 - Online Programming
Designated Description
Designated Description
0 : No
1 : Increment
2 : Decrement
01~40 : starting position
01~08 : data count
001~999 ; sequential step
01~99 : same number repeat quantity
00000001~99999999 :
For incremental numbering, the wrap
around value when it reaches the
maximum value.
For decrement numbering, the minimum
value.
00000001~99999999
For incremental numbering, the
maximum value.
For decrement numbering, the wrap
around value when it reaches the
minimum value.
56