3-41. Drink dispenser - Berg (V2.10), E-protocol (V2.80)
Berg liquor dispenser (Basic / Generic) is supported.
System Configuration
HX-series
Communication settings
Baud Rate
Data Bits
Parity
Stop Bits
Handshaking
Cable pin layout
POS
3
TXD
2
RXD
5
GND
8
CTS
Additional Programs
Configure > External Device > Drink Dispenser
Program > PLU > Option > non correctable item
In case the above setting is enabled, Item correction on such PLUs is not possible.
Also, Transaction void for the transaction including such PLU is not possible, either.
Complimentary operation is available.
Serial (RS-232C)
Berg Basic
Berg Generic
9600bps
2400bps
8
8
None
None
1
1
None
DTR (※1)
Dispenser
RXD
TXD
GND
DTR
Model: = Berg Basic, Berg Generic
Liquor dispenser (Berg)
(*1) Note: This is optional,
the interface works fine without it.