AC Voltage Measurements

OFF
~
V
~
A
V
A
OBSERVE ALL SAFETY PRECAUTIONS AND WARNINGS
Operating Procedure
1. The voltage input connectors are color-coded 4 mm banana jacks
located on the base of the instrument. When making voltage connec-
tions, be sure to observe the proper polarity and connection integrity.
Select the appropriate termination (test probe or clips) for the application.
Insert the RED test lead into the
into the
COM
2. Turn on the instrument using the rotary selector to the voltage mea-
surement function V~. Selection is confirmed with a short beep when
exiting OFF.
3. Touch or connect the voltage test leads to the circuit under test.
4. Take a reading from the display. Voltage measurements are possible
from 50 mV to 600 Vrms, and to 1500 V Peak
Clamp-On Harmonic Probe Model
AEMC
Model 725
HARMONIC METER
I N S T R U M E N T S
!
0
1
2
3
4
jack.
AC
V
RMS
5
600
V
jack and the BLACK test lead
+