AEMC 725 User Manual page 12

Clamp-on harmonic probe
Table of Contents

Advertisement

Material:
Case: Gray Lexan
®
920A, UL 94 V2
Jaws: Red Lexan
®
500R, 10% fiberglass, UL 94 V0
LCD lens: Crystal Lexan
®
920A, UL 94 V1
Mechanical:
Envelope Protection: IEC 529: IP 40
Drop Test: IEC 1010: 1m
Vibration: IEC 68-2-6
Shocks: IEC 817
SAFETY
Protection Level:
Double insulation IEC 1010-1, 600 V Category III, Pollution degree 2.
Max. Working Voltage: 600 Vrms
Dielectric Test: 5.5 kV, 50/60 Hz, 1 minute
Overload Protection:
Voltage: 1.5 kV Peak permanent
Current: 1000 A AC (50/60 Hz) permanent
Agency Approvals: CSA, GS, VDE, CE pending
ELECTROMAGNETIC COMPATIBILITY
Electrostatic Discharge:
IEC 801-2: No influence: 4 kV class 2
Non-destructive: 15 kV class 4
RF: IEC 801-3: No influence: 3 V/m class 2
Minor influence: 10 V/m class 3
Transients: IEC 801-4: No influence: 2 kV class 4
Electric shocks: IEC 801-5: No influence: 6 kV class 3
10
Clamp-On Harmonic Probe Model

Advertisement