APV
APV_UF3-UFR3_UK-7_082017.indd
9
9.
Technical Data
9.1.
General data
-
Product-wetted parts:
-
Other parts:
-
Seals: standard design
-
option:
-
max. line pressure
-
max. operating temperature:
-
short-term load:
-
air connection (for hose):
-
control pressure for seat lift actuator:
Depending on the size of the spring cylinder, the response
pressure can be adjusted variably or up to max. 10 bar. (or
according to drawing data)
-
The minimum response pressure can be > 0 bar depending on the
valve mounting position and the friction of the shaft seal.
Use dry and clean control air only!
9.2.
Compressed air quality
-
Compressed air quality:
-
Content of solid particles: quality class 3,
-
Content of water:
-
Content of oil:
The oil applied must be compatible with Polyurethane elastomer
materials.
1.4404 (DIN EN 10088)
1.4301 (DIN EN 10088)
EPDM
HNBR, VMQ, FPM
10 bar or acc. to
drawing data
135°C EPDM, HNBR
*FPM, *VMQ
140°C EPDM,
HNBR
*FPM, *VMQ
*(no steam)
6 x 1mm
10 bar max. / 6 bar min.
quality class according to ISO 8573-1
max. number of particles per m³
10000 of 0,5 μm < d ≤ 1,0 μm
500 of 1,0 μm < d ≤ 5,0 μm
quality class 3,
max. dew point temperature - 20 °C
For installations at lower temperatures
or at higher altitudes, additional
measures must be considered to reduce
the pressure dew point accordingly.
quality class 1,
max. 0,01 mg/m³
DELTA UF3 (A) / UFR3 (A)
Instruction Manual: UK-7
UK
Relief Valve
Need help?
Do you have a question about the APV DELTA UF3(A) and is the answer not in the manual?