3.3

Function List of CC-Link IE Field Network

The following table lists the functions of CC-Link IE Field Network. For details on the functions, refer to the following.
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
Cyclic transmission
: Available, : Partially available, : Not available
Function
Communications
Communications
with other stations
using RX and RY
Communications
using RWr and
RWw
Access to devices
Link refresh
and link devices
Direct access to link
devices
Cyclic data integrity assurance
Interlink transmission
Mode selection for cyclic transmission
Sequence scan synchronization
specification
Cyclic transmission punctuality assurance
Input status setting for data link faulty
station
Output status setting for CPU STOP
Output status setting for CPU stop error
Cyclic transmission stop and restart
*1 The "High-Speed Remote Net" mode can be set only for the master station.
Availability of "High-Speed Remote Net" depends on the firmware version of the CC-Link IE Field Network-equipped master/local
module.
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
Transient transmission
: Available, : Partially available, : Not available
Function
Communications within the same network
Communications with different networks
Dedicated instruction
3 FUNCTION LIST
40
3.3 Function List of CC-Link IE Field Network
Description
Communicates I/O data in units of bits between the master station and other
stations.
Communicates I/O data in units of words between the master station and other
stations.
Automatically transfers data between the link device of the master/local
module and the device of the CPU module
Directly accesses the link devices of the master/local module from the
program.
Assures the cyclic data integrity in units of 32 bits or station-based units.
Transfers data in the link devices of the master station or submaster station to
another network module on a relay station.
Selects the mode for optimizing the performance of cyclic transmission based
on the cyclic transmission and transient transmission frequency. The mode is
selected from "Normal", "High-Speed", or "High-Speed Remote Net".
Selects whether link scan is set to asynchronous or synchronous with the
sequence scan of the CPU module.
Keeps the link scan time constant by setting the constant link scan time.
Selects whether input data from another station where a data link error occurs
is cleared or held.
Selects whether cyclic data output is held or cleared when the CPU module
mounted with a master/local module is set to STOP.
Selects whether cyclic transmission output is held or cleared when a stop error
occurs in the CPU module which a master/local module is mounted with.
Stops the cyclic transmission during debugging and other operations. (Data
reception from a slave station and data sending from the own station are
stopped.) Also, the stopped cyclic transmission is restarted. Transient
transmission does not stop.
Description
Performs the transient transmission to other stations using dedicated
instructions and the engineering tool.
Performs the transient transmission seamlessly to stations on different
networks using dedicated instructions and the engineering tool.
An instruction for using functions of modules. ( MELSEC iQ-R
Programming Manual (Module Dedicated Instructions))
Availability
Master
Local
station,
station
submaster
station
*1
Availability
Master
Local
station,
station
submaster
station