WARNING NOTE:
Properly installed, operated and maintained this
stove will not emit fumes into the dwelling. In the
event of a gas escape or if you can smell gas then
the following immediate action should be taken:
(a) Immediately turn off the gas supply at the
meter/emergency control valve.
(b) Extinguish all sources of ignition.
(c) Do not smoke.
(d) Do not operate any electrical light or power
switches (ON or OFF).
(e) Ventilate the building(s) by opening doors &
windows.
(f) Ensure access to the premises can be made.
Please report the incident immediately to Gas
Networks Ireland (1850 20 50 50), National Gas
Emergency Service Call Centre (0800111999 for
UK or 0800002001 for Northern Ireland) or in the
case of LPG, the gas supplier whose details can be
found on the bulk storage vessel or cylinder.
The gas supply must not be used until remedial
action has been taken to correct the defect and the
installation has been recommissioned by a compe-
tent person.

BATTERY REPLACEMENT

The Gas Valve Control Box requires four AA
Batteries which are fitted by removing the front
cover and inserting the batteries into the housing as
shown in Fig 48. The Remote Control requires two
AAA Batteries which are fitted by removing the back
cover and inserting the batteries into the housing as
shown in Fig 49.
NOTE:
It is recommended to use Duracell
Ultra
Rechargeable batteries are not to be
used.
batteries should last approximately
12 months.

SERVICING

Before carrying out any maintenance, ensure
that the Stove is cold and isolate the main gas
supply.
ALL SERVICING & REPAIR WORK MUST BE
CARRIED OUT BY A QUALIFIED/COMPETENT
GAS ENGINEER.
Power
alkaline
batteries.
Under
normal
conditions
Fig.48
Fig.49
The following is the recommended procedure for
servicing the Stove:
1.
Remove
described in the Installing the Stove section.
2.
Carefully remove the Ceramic Logs and
Embers.
3.
Use a vacuum cleaner and a soft brush to
clean the pilot assembly and both injectors. It
may be easier to access the Injector by
removing the throttle.
NOTE:
NEVER MODIFY OR BEND THE
THERMOCOUPLE.
4.
Turn on the gas supply and check for leaks.
5.
Check the operation of the burners & pilot.
6.
Clean the Ceramic Logs & Embers external
to the building using a soft brush and a
vacuum cleaner. Any damaged parts should
be replaced.
7.
Replace the Ceramic Logs and Embers -
see Fuel Bed Arrangement Section.
8.
Clean the Firebox Glass Panel & refit same.
9.
Refit the Front Fixing Brackets, Front
Casting, Bottom Heat Shield & Fire Door.
10.
Check the flue system & terminal ensuring
that the terminal vent is fully clear.
11.
Light the stove and test the pressure
settings (see Pressure Check).
12.
Test the gas valve and gas system for
soundness.
13.
Check the safe operation of the Stove.
14.
Complete the Service Records Log on the
back of the manual.