GLASS REPLACEMENT

(a) Open the firedoor fully.
(b) Remove the top glass retaining bracket by
removing the two fixing screws (see Fig. 22).
(c) Lift the glass free off the bottom retaining brack-
et.
(d) Before fitting the new glass, check the glass
sealing on the door frame and replace if neces-
sary.
Fig.22
Glass Retaining Bracket Screws

CO ALARM

The fitting of CO Alarms in the same room as the
appliance is a compulsory requirement under cur-
rent Building Regulations. For ROI an additional CO
Alarm must be fitted either inside each bedroom or
within 5 metres of the bedroom door, refer to
Building Regulations Part J. Further guidance on the
installation of a carbon monoxide alarm is available
in BS EN 50292:2002 and from the alarm manufac-
turers instructions.
Provision of an alarm must not be considered a
substitute for either installing the appliance
correctly or ensuring regular servicing and
maintenance of the appliance and chimney
system.
WARNING:-
If the CO Alarm sounds unexpectedly:-
1. Open Doors and windows to ventilate the
room and then leave the premises.
2. Let the fire go out.