GILES GVH Series Operation & Service Manual page 37

Ventless recirculating hood system
Table of Contents

Advertisement

Overview
3-2.
Hood Front & Filter Chamber
Item
Description
1
Filter Access Door
2
Double Baffle Filter
3
4
Charcoal Filter
5
Air Exhaust Outlet w/Diverter
6 +
Grease Drip Cup
7*
Appliance Receptacle
8 +
Under-Hood Light
*
Optional
+ Not Seen
EAC Filter Cell
Provides access to the Baffle Filter, EAC and Charcoal Filter. This
door must be closed and latched for the unit to operate.
First stage of the grease extraction and air-cleaning system. This filter
is easily removed for daily cleaning.
EAC Filter is an electrostatic device that removes grease vapor and
smoke generated during cooking. The EAC Cell must be cleaned
daily.
Charcoal Filter helps to eliminate cooking aromas from the discharge
air. This Filter should be replaced monthly. NEVER attempt to clean
and re-use the Charcoal Filter. Replace with new filter
approximately every 30 days.
The Exhaust Outlet atop of the unit exhausts the filtered air back
into the room and features an airflow diverter to direct air to the
sides and rear. No clearance is actually required between the
diverter top and ceiling, or overhead obstructions. It is adviseable
to allow some clearance to make moving the unit easier if needed.
The Grease Drip Cup catches grease condensate generated at the
Baffle Filter. This container should be checked often, emptied as
needed, and cleaned daily.
Optional interlocked appliance receptacle (NEMA), 50A max.
Allows the under-hood appliance to be plugged directly into the
hood, eliminating need for separate appliance power supply.
Fluorescent lighting illuminates the appliance area under the hood.
Model: GVH-C, GVH-F
Function
27