FSH-2, Operations & Service Manual FSH-2A-99 Model: FSH-2A-99 Giles Enterprises, Inc. An ISO 9001 Registered Company • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Fax: 334.239.4117 • Website: www.gfse.com Service Hotline (Toll Free): 800.554.4537 (USA & Canada Only) FOODSERVICE EQUIPMENT Form No.
Page 3
Giles Enterprises, Inc., representative. • Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured. •...
Safety Model: FSH-2, FSH-2A-99 Safety Safety Overview The instructions contained in this manual have been prepared to aid you in learning the proper procedures for installing and servicing your new unit. Throughout this manual, safety precautions are identified through the use of the safety alert symbol and three signal words: DANGER, WARNING, and CAUTION.
Safety Model: FSH-2, FSH-2A-99 Specific Safety Precautions For your safety, please observe the following precautions when operating or servicing your Giles equip- ment. Read the following important safety information to avoid personal injury and/or damage to the equipment. DANGER •...
Page 9
Safety Model: FSH-2, FSH-2A-99 CAUTION • The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Always refer to local electrical code to ensure proper grounding of this or any other electrical equipment. Always consult with an electrician or other qualified service person to ensure breakers and wiring are of suf- ficient rating and gauge for the equipment being operated.
Page 10
Safety Model: FSH-2, FSH-2A-99 NOTE: • Consultation with an HVAC specialist may be required for some installa- tions to confirm proper room air exchange and the heat load capabilities of the on site AC system. • Exhaust ventilation is recommended for areas in which recirculating hoods are used. We recommend 50 CFM per linear foot of hood space.
Model: FSH-2, FSH-2A-99 1. Introduction Congratulations on the purchase of your new Giles Free Standing Ventless Hood, Model FSH-2 or FSH-2A- 99 manufactured by Giles Enterprises, Inc., Montgomery, Alabama (USA), hereafter referred to as "Giles". The Free Standing Ventless Hood is a product of extensive research and testing. Every unit is thoroughly inspected and tested prior to shipment.
Installation Model: FSH-2, FSH-2A-99 2. Installation This section provides a summary of the procedures necessary for proper installation of your unit. To help pre- vent personal injury or equipment damage, please ensure the following steps are taken. 2-01. Location NOTE: •...
Using appropriate tools, carefully remove the wooden crating from around the unit. Carefully remove the unit from the shipping platform. The FSH-2 or FSH-2A-99 is extremely heavy, see Section 1-03.04. for unit weights. Great care should be taken when lifting or moving the unit to prevent personal injury or equipment damage.
Installation Model: FSH-2, FSH-2A-99 2-03.03. Hood and Appliance Interlock Connection This interlock circuit will disable power to the Appliance installed under the Hood if any of the following occurs: • Any Filter becomes excessively dirty, not allowing proper air flow through the Hood.
Gas appliances or appliances other than the types stated are not approved. 2-04.01. Fryer Limitations WARNING • The Hoods are design for Electric Fryers Only!!! DO NOT USE ANY GAS APPLIANCES UNDER THE FSH-2 or FSH-2A-99!! Max. Shortening Max Cooking Surface Hood Max.
Model: FSH-2, FSH-2A-99 2-05. Fire Suppression System The fire suppression system used in the Giles Ventless Hood is an ANSUL® R-102 Restaurant Fire Suppression System (Standard UL 710B Listed). Final installation, charging and certification of the system must be performed by an authorized Ansul distributor in accordance with the system’s list- ing.
Installation Model: FSH-2, FSH-2A-99 2-05.02. Fire Exinguishing Nozzles and Tank Location All nozzles have been factory installed and aligned in the proper operating position. DO NOT MOVE OR ADJUST. Plenum Nozzle Giles P/N 46426 Plenum Nozzle Giles P/N 46426 FSH-2 Appliance Nozzle...
Installation Model: FSH-2, FSH-2A-99 2-05.03. Manual Pull Diagram This Hood requires use of the ANSUL® R-102 Standard for a Manual Activation System. The Manual Pull Station must be mounted on a near-by wall near the path of egress and connected to the Hood. The Manual Activation System is used to activate the Fire Extinguisher System from a remote location.
Installation Model: FSH-2, FSH-2A-99 2-06. Restraining Device Any Fryer placed under this Hood must be secured so that it can not move from under the Hood. The fol- lowing depicts an example of a suitable restraining device. The restraining device must be appropriate for the appliance being used and will vary depending on the make and model of Fryer.
Model: FSH-2, FSH-2A-99 3. Overview The following section provides a brief overview of the components, functions, and accessories of the Free Standing Hood, Model FSH-2, FSH-2A-99. Please review this section carefully before proceeding further. UV Sight Window Filter Chamber (optional) Figure 3-01.
Overview Model: FSH-2, FSH-2A-99 3-01. Filter Chamber Not Shown...
Page 29
DO NOT touch Lamp with bare hands This Filter helps to remove unwanted aromas generated dur- ing cooking. It should be replaced monthly. NEVER attempt to clean the Charcoal Filter. Keeping a spare filter (Giles Charcoal Filter #30248) for quick exchange when needed can avoid down-...
Overview Model: FSH-2, FSH-2A-99 3-02. Control Panel...
Page 31
Overview Model: FSH-2, FSH-2A-99 3-02. Control Panel Item Description Function ON Indicator Indicates that the Electronic Air Cleaner (EAC) is powered. The EAC (EAC Status L.E.D.) is operating normally when this is the only light illuminated. Indicates that the EAC has become excessively dirty. Do not rely WASH Indicator upon this light as a signal for routine cleaning.
Overview Model: FSH-2, FSH-2A-99 3-03. Accessories (Included) Part Description/Part Number Function Baffle Filter Removes grease-laden vapor 42300 contaminants from the air Removed smoke and fine EAC Filter grease-laden contaminants from 20520 the air stream. Helps to remove unwanted Charcoal Filter...
Page 33
Overview Model: FSH-2, FSH-2A-99 3-03. Accessories (Included) Part Description/Part Number Function Container for holding degreas- EAC Soak Tank ing solution used to clean EAC 39327 cell daily. Part Description/Part Number Function Sanitizes discharge air and the UV Lamp hood’s plenum area. Helps with 90226 controlling unwanted aromas.
Operation Model: FSH-2, FSH-2A-99 4. Operation This section describes operation of the Hood and filter maintenance procedures. 4-01. Hood Operation This section describes how to start the Ventless Hood. Ensure all Filters and UV Lamp, if equipped, are in place and correctly installed before operating the unit.
Operation Model: FSH-2, FSH-2A-99 4-02.04. Baffle Filter Missing If the Baffle Filter is either missing or not properly installed, the Filter Missing Light will illuminate and power to the under-hood appli- ance is disabled until the condition is corrected. See Section 7-02.03 Baffle Filter Installation.
Operation Model: FSH-2, FSH-2A-99 4-02.07. EAC Filter Installation Filter Access Cover Hole on back of Filter must align with this pin. EAC Air Flow Arrow located on the left or right of the EAC Handle and must point up 4-02.08.
Operation Model: FSH-2, FSH-2A-99 4-02.09. EAC Filter Cleaning CAUTION • Do not bend the fins or break the ionizer wires on the EAC cell as this will prevent proper func- tion and potentially void the warranty. Ionizer Wires (9) Required Fins 1.
Operation Model: FSH-2, FSH-2A-99 4-02.10. Charcoal Filter Removal Filter Access Cover 4-02.11. Charcoal Filter Installaton Switch must be actuated Hood Filter Cover “Blue” mat side UP by the filter Note airflow arrow on label.
Operation Model: FSH-2, FSH-2A-99 4-02.12. Charcoal Filter Missing If the Charcoal Filter is missing or not properly installed, the Filter Missing Light will illuminate and power to the under-hood appli- ance is disabled until the condition is corrected. See Section 4-02.11 Charcoal Filter Installation.
Operation Model: FSH-2, FSH-2A-99 4-02.14. Ultraviolet Lamp Removal 1. Place hood power switch in the OFF position. 2. Remove Filter Access Cover 3. Disconnect UV Lamp wiring harness from power supply wiring harness . 4. Loosen and remove (2) thumb screws and remove Lamp Guard.
Operation Model: FSH-2, FSH-2A-99 4-02.16. Ultraviolet Lamp Cleaning CAUTION • DO NOT touch or handle bulb portion of UV Lamp with bare hands. This will greatly reduce lamp life. Cleaning should be performed every 30 days 1. Place hood power switch in the OFF position.
4-03.01. Monthly Interlock Check The Giles Ventless Hood System incorporates an Interlock System to ensure the unit is operates in a safe and effective manner. Testing of the Interlock System should be conducted MONTHLY in the following manner. Use the form located in Section 4-06.06 Maintenance and Service Log, place a check in the box that corre- sponds to the test being performed.
Fire Suppression System is to be performed semi-annually by qualified fire equip- ment service personnel. Such maintenance shall consist of the following (Consult the Giles Enterprises Design Installation, Recharge and Maintenance Manual for complete servicing guidelines).
Hood Cleaning Model: FSH-2, FSH-2A-99 5. General Hood Cleaning This section describes Hood cleaning. CAUTION •• DO NOT steam clean. •• DO NOT use products containing chlorine. •• DO NOT use abrasive products, steel wool or scouring pads. Before performing any cleaning activities, disconnect Hood and Appliance power at the main breaker.
Troubleshooting Model: FSH-2, FSH-2A-99 6. Troubleshooting This section describes troubleshooting procedures for the FSH-2, FSH-2A-99. Refer to the wiring diagram provided with the unit as needed for more detailed analysis. DANGER • Electrical troubleshooting procedures should be performed ONLY by qualified service personnel.
Page 52
Troubleshooting Model: FSH-2, FSH-2A-99 6-01. Troubleshooting Procedures (Cont’d.) Problem Probable Cause Repair Procedure Fryer will not turn on and ... a. Baffle Filter missing a. Install Baffle Filter • Hood Power Light is ON b. Baffle Filter not installed b. Reinstall Baffle Filter •...
Please visit our website at: www.gfse.com or e-mail services@gfse.com. The goal of the Giles team is to provide you with the highest quality service and assistance possible. To help us accomplish this please have the following information readily available when calling, along with the nature of the problem you are encountering.