Hide thumbs Also See for FSH-5:
Table of Contents

Advertisement

Operations & Service Manual
FSH-5 & FSH-6
Models: FSH-5 & FSH-6
Giles Foodservice Equipment
ISO 9001 Registered • Committed to Quality
2750 Gunter Park Drive West • Montgomery, AL 36109 USA
Phone: 334.272.1457 • Fax: 334. 239.4117 • Website: www.gfse.com
Toll Free: 800.554.4537
(USA & Canada Only)
Form No. 64898 (Rel. Date: 07/1999; Rev. Date: 04/2017; Rev. G)

Advertisement

Table of Contents
loading

Summary of Contents for GILES FSH-5

  • Page 1 Operations & Service Manual FSH-5 & FSH-6 Models: FSH-5 & FSH-6 Giles Foodservice Equipment ISO 9001 Registered • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Phone: 334.272.1457 • Fax: 334. 239.4117 • Website: www.gfse.com Toll Free: 800.554.4537...
  • Page 3: Limited Warranty

    During the Limited Warranty period, Giles Enterprises, Inc. will replace or recondition, at its factory, any part or parts of this unit which Giles Enterprises, Inc. inspectors judge defective, provided the unit has been sub- jected to normal usage, properly installed, operated and serviced. This Limited Warranty does not cover cos- metic damage, and damage due to acts of God, accident, misuse, alteration, negligence, abuse of the Giles Foodservice Equipment or the use of unorthodox repair methods.
  • Page 5: Table Of Contents

    Overall Dimensions for FSH-5 & 6 (Ceiling Mount) ....... . .
  • Page 6 Model: FSH-5 & FSH-6 Table Of Contents Operation & Filter Maintenance........27 4-01.
  • Page 7: Safety

    Safety Model: FSH-5 & FSH-6 afety Safety Overview The instructions contained in this manual have been prepared as an aid to learning the proper procedures for installing and servicing this new unit. Throughout this manual, safety precautions are identified through the use of safety alert symbols and three key words: DANGER, WARNING, and CAUTION.
  • Page 8: Specific Safety Precautions

    Specific Safety Precautions For your safety, please read and observe the following important safety precautions when operating or servicing your Giles equipment to avoid personal injury and/or damage to the equipment. DANGER • Turn off the unit and disconnect main power supply before cleaning or performing maintenance.
  • Page 9 • Exhaust ventilation is recommended for areas in which recirculating hoods are used. Giles recommends 50 CFM per linear foot of hood space. This amount could vary based on local codes and the site-specific installation requirements.
  • Page 10 viii...
  • Page 11: Introduction

    Model: FSH-5 & FSH-6 ntroduction Thank you for the purchase of a new Giles Ventless Recirculating Hood System, Model FSH-5 or FSH-6; manufactured by Giles Foodservice Equipment, Montgomery, Alabama (USA), hereafter referred to as "Giles". These two models are available as either a ceiling hung, or a stand mounted model. The stand mounted version measures 72” from the floor to the bottom edge on the hood skirt.
  • Page 12: Specifications

    Model: FSH-5 & FSH-6 Introduction 1-4. Specifications 1-4.1. Overall Dimensions for FSH-5/6 (Ceiling Mount model) FSH-5 FSH-6 60-9/16 [1538.3] 72-9/16 [1843.1] 55-1/8 [1400.2] C to C 67-1/8 [1705.0] C to C 59-15/16 [1521.9] 71-15/16 [1705.0]...
  • Page 13: 1-4.2. Overall Dimensions For Fsh-5 & 6 (Stand Mount)

    Introduction Model: FSH-5 & FSH-6 1-4. Specifications 1-4.2. Overall Dimensions for FSH-5/6 (Stand Mount model) FSH-5 FSH-6 60-9/16 [1538.3] 72-9/16 [1843.1] 56-7/16 [1433.5] 68-7/16 [1738.3] 61-3/4 [1568.5] 73-3/4 [1873.3] (with 72” Stand Mt) 72 [1828.8] 117-3/16 [2976.6] 58 9/16 DOOR OPEN [1487.5 DOOR OPEN...
  • Page 14: 1-4.3. Listings

    Model: FSH-5 & FSH-6 Introduction 1-4. Specifications 1-4.3. Regulatory Listings 1-4.4. Hood Weights Hood Crated Weight Uncrated Weight FSH-5 664 lbs [302 kg] 464 lbs [211 kg] FSH-6 733 lbs [333 kg] 553 lbs [251 kg]...
  • Page 15: Installation

    Model: FSH-5 & FSH-6 Installation This section summarizes procedures necessary to install the new FSH-5 or FSH-6 Hood. Before installing or servicing this equipment, please read the contents of this manual thoroughly. Following these procedures will help to ensure a safe and proper installation.
  • Page 16: Location

    • Exhaust ventilation is recommended for areas in which recirculating hoods are used. Giles recommends 50 CFM per linear foot of hood space. This amount could vary based on local codes and site-specific installation require- ments.
  • Page 17: Hood Skirt Installation

    Installation Model: FSH-5 & FSH-6 2-03. Hood Skirt Installation Hood Skirts MUST be installed on ceiling mount Hoods to ensure proper capture performance. NOTE: 1. Peel all protective film from parts before assembling. 2. Apply a bead of Hi-Temp Silicone (included) to the top flanges of both Side Skirts.
  • Page 18: Hood Stand Installation

    Model: FSH-5 & FSH-6 Installation 2-04. Hood Stand Installation (Stand Mount model) BEAD OF HIGH TEMP STEP 1 SILICONE (INCLUDED) BEAD OF HIGH TEMP SILICONE (INCLUDED) BEAD OF HIGH TEMP SCREW SILICONE (INCLUDED) LEFT SIDE WASHER RIGHT SIDE NOTE NO HOLES ON BOTTOM FLANGE...
  • Page 19: Cooking Appliance Limitations And Clearances

    Installation Model: FSH-5 & FSH-6 2-05. Cooking Appliance Limitations and clearances 2-05.1. Fryer Limitations (Electric Appliances Only) Max. Max Cooking Max Cooking Hood Max. Temp. Max. kW Input Shortening Surface (per Surface (Total Capacity Fryer) all Fryers) FSH-5 400° 80.0 380 Sq.
  • Page 20: Oven Limitations

    Model: FSH-5 & FSH-6 Installation 2-05.3. Oven Limitations (Electric Appliances Only) Max. kW Input Hood Max. Temp. (Total all Ovens) FSH-5 500° FSH-6 500° 2-05.4. Oven Clearances 72 max [1828.8] ceiling mount 68 max [1727 .2] stand mount 60 max [1522.0] ceiling mount 56 max [1422.4] stand mount...
  • Page 21: Griddle Limitations

    Installation Model: FSH-5 & FSH-6 2-05.5. Griddle Limitations (Electric Appliances Only) Hood Max. Temp. Max. kW Input Max Cooking Surface FSH-5 400° 48 X 26 FSH-6 400° 60 X 26 2-05.6. Griddle Clearances (side-to-side overhang requirement does not apply with Stand Mount model) 0”...
  • Page 22: Range Limitations

    Model: FSH-5 & FSH-6 Installation 2-05.7. Range Limitations (Electric Appliances Only) Hood Max. Temp. Max. kW Input Max Burners FSH-5 400° FSH-6 400° 2-05.8. Range Clearances (side-to-side overhang requirement does not apply with Stand Mount model) 0” when using 0” when using...
  • Page 23: Hood Electrical Requirements

    Installation Model: FSH-5 & FSH-6 2-06. Hood Electrical Requirements WARNING • Consult a professional qualified electrician to ensure the installation complies with all electrical specifications and that the unit is properly grounded in accordance with local building code. • Improper installation, adjustment, alteration, service, or maintenance could result in serious injury, even death;...
  • Page 24: Routing Power Wires

    Model: FSH-5 & FSH-6 Installation 2-06.2 Routing Power Wires 2-06.3 Hood and Appliance Interlock Diagram...
  • Page 25: Fire Suppression System Installation

    Fire Suppression System Installation It is a requirement that the Giles FSH-5 & 6 Ventless Hood System be protected by a UL Listed fire suppression sys- tem. Installation is to be performed by an Authorized Fire Suppression Agent in accordance with the system listing.
  • Page 26: 2-07.2. Fire Suppression Fusible Links

    Model: FSH-5 & FSH-6 Installation 2-07.2. Fire Suppression Fusible Links 285° (Factory installed) 165° (Ansul P/N 56811) 165° (Ansul P/N 56811) 165° (Ansul P/N 56811) 2-07.3. Appliance Nozzles Center Nozzles over cooking sur- face(s) Appliance Nozzle, (2) minimum, Sized and Located by Local...
  • Page 27: 2-07.4. Fire Extinguisher Nozzle Locations

    Installation Model: FSH-5 & FSH-6 2-07.4. Fire Extinguisher Nozzle Locations Plenum Nozzle Plenum Nozzle (Factory installed) (Factory installed) Appliance Nozzle, (2) minimum, Sized and Located by Local Plenum Nozzle Authorized Fire Suppression (Factory installed) Agency (Supplied by Customer) 2-07.5. General Maintenance The fire extinguishing system should be maintained as outlined in the Standard for Wet Chemical Extinguishing Systems, NFPA 17A and in accordance with the instructions of the system’s installer.
  • Page 28 Model: FSH-5 & FSH-6 Installation NOTES:...
  • Page 29: Overview

    Overview Model: FSH-5 & FSH-6 3. Overview This section provides a brief overview of the FSH-5 and 6 Hood ... the components, their functions, and the associat- ed accessories. Please review carefully before proceeding any further. Hood Exhaust Control Panel Figure 3-01.
  • Page 30: Control Panel

    Model: FSH-5 & FSH-6 Overview 3-01. Control Panel * ILS Only (not shown)
  • Page 31 Overview Model: FSH-5 & FSH-6 3-01. Control Panel Item Description Function Light Switch Turn the under-hood lights ON and OFF. Hood equipped with ILS Option ONLY ... After the Power Switch is PUSH to START in the ON position, push and hold down PUSH to START Button for Button 5 seconds start the Hood fan.
  • Page 32: Filter Chamber And Exhaust

    Model: FSH-5 & FSH-6 Overview 3-02. Filter Chamber and Exhaust...
  • Page 33 Overview Model: FSH-5 & FSH-6 3-02. Filter Chamber and Exhaust Item Function Provides access to the Pre-Filter, EAC and Charcoal Filters. Both Hood Filter Door (2) doors must be closed and latched for the unit to operate. The Baffle Filters are the first stage of the grease extraction and air- cleaning system of the Hood.
  • Page 34: Accessories (Included)

    Model: FSH-5 & FSH-6 Overview 3-03. Accessories (Included) Part Description/Part Number Function (2) Baffle Filter Removes large particle contaminant from the air. P/N 42300 (2) Pre-Filter Removes additional grease-laden P/N 91707 vapors from the air. EAC Filter P/N 20521 (LEFT)
  • Page 35 Overview Model: FSH-5 & FSH-6 3-03. Accessories (Included) Part Description/Part Number Function (2) Charcoal Filter Helps remove odors from the air P/N 32056 EAC Soak Tank Used for soaking and cleaning P/N 39327 EAC filter.
  • Page 36 Model: FSH-5 & FSH-6 Overview Notes:...
  • Page 37: Operation & Filter Maintenance

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4. Operation & Filter Maintenance This section describes Hood operation and filter maintenance. 4-01. Hood Operation Starting the Ventless Hood ... Make sure all Filters are in place and Filter Access Doors are closed before attempting to operate the unit.
  • Page 38: Baffle Filter Removal

    Model: FSH-5 & FSH-6 Operation & Filter Maintenance 4-02.2. Baffle Filter Removal Place in OFF position...
  • Page 39: Baffle Filter Installation

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4-02.3. Baffle Filter Installation Front View Position filters such that the baffles are in a vertical orientation. Switch arm must be actuated by the Baffle Filter as shown 4-02.04. Baffle Filter Missing...
  • Page 40: Baffle Filter Cleaning

    Model: FSH-5 & FSH-6 Operation & Filter Maintenance 4-02.5. Baffle Filter Cleaning Grease Baffle Filters should be cleaned daily. Place in sink and clean with hot soapy water, or a mild bio-degradable degreaser. Dry thoroughly and reinstall in the unit.
  • Page 41: Pre-Filter Installation

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4-02.7. Pre-Filter Installation Pre-Filter Metal mesh side Open Door, align in track, push in Paper side Paper side Pre-Filter Switch roller must be actuated by the Pre- Filter frame. Front View Close Door 4-02.8.
  • Page 42: Pre-Filter Replacement

    Model: FSH-5 & FSH-6 Operation & Filter Maintenance 4-02.9. Pre-Filter Replacement WARNING NEVER attempt to clean and re-use the Pre-Filters. This could cause damage to the unit. Replace Pre-Filters every 7-10 days ... Use Replacement Part No. 91707. NOTE: When filters are changed, always record the installation date in the space provided on the filter label.
  • Page 43: Eac Filter Installation

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4-02.11. EAC Filter Installation Right EAC Air Left EAC Air Filter Contact Hood Contact Flow Arrow Flow Arrow Plate Plate EAC alignment EAC Filter Folding Handle IMPORTANT! EAC Cells are NOT interchangeable right to left or visa- versa.
  • Page 44: 4-02.12. Eac Filter Status

    Model: FSH-5 & FSH-6 Operation & Filter Maintenance 4-02.12. EAC Filter Status Three (3) LED indicator lights on the Control Panel display the status of each EAC Filter system. The EAC Filter cell is in place, powered and operating properly. These two LED’s illuminate to indicate that the WASH &...
  • Page 45: 4-02.14. Charcoal Filter Removal

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4-02.14. Charcoal Filter Removal Place in OFF position Charcoal Filter Door open, pull straight out. Front View...
  • Page 46: 4-02.15. Charcoal Filter Installation

    Model: FSH-5 & FSH-6 Operation & Filter Maintenance 4-02.15. Charcoal Filter Installation Door open, align in track, push Blue Fiber-fill Side straight in. Charcoal Filter Switch roller must be actuated by the Charcoal Filter frame. Front View Close Door 4-02.16. Charcoal Filter Missing...
  • Page 47: 4-02.17. Charcoal Filter Replacement

    Operation & Filter Maintenance Model: FSH-5 & FSH-6 4-02.17. Charcoal Filter Replacement WARNING NEVER attempt to clean and re-use the Charcoal Filters. This could cause damage to the unit. Replace the Charcoal Filter approximately every 30 days. Use Replacement Part No. 32056. Please take the time to record the installation date in space provided on the new filter’s label.
  • Page 49: Hood Cleaning And Maintenance

    Monthly Interlock Check The Giles Ventless Hood System is designed with various interlock devices to ensure that the unit operates safely and effectively. The interlocks should be tested MONTHLY as described below. Use the Maintenance & Service Log as a record of these inspection.
  • Page 50: Semi-Annual Fire Suppression System

    Model: FSH-5 & FSH-6 Cleaning & Maintenance 5-3. Semi-Annual Fire Suppression System Service Servicing and inspection of the fire suppression system must be performed by technicians from a certified fire protection equipment company. As a minimum, field inspection of the Fire Suppression System must be conducted semi-annually.
  • Page 51: Maintenance And Service Log

    Cleaning & Maintenance Model: FSH-5 & FSH-6 5-6. Maintenance & Service Log Check Initial/Date Check Initial/Date ABC 1/2/03 1 Baffle Filter Check Section 5-1. Must be performed by 2 Pre-Filter Check Section 5-1. a certified fire protection 3 EAC Filter Check Section 5-1.
  • Page 52 Model: FSH-5 & FSH-6 Cleaning & Maintenance Notes:...
  • Page 53: Troubleshooting

    Model: FSH-5 & FSH-6 6. Troubleshooting This section describes basic troubleshooting procedures for the FSH-5 & 6 . Troubleshooting by the User should be limited to operational and procedural issues only. Qualified service company technicians should perform any more in-depth and/or electrical system troubleshooting.
  • Page 54 Model: FSH-5 & FSH-6 Troubleshooting 6-1. Troubleshooting Procedures (continued) Problem Probable Cause Corrective Action Appliance will not heat a. Either one or more of the Baffle a. Install the missing Filter, or check Filters, Pre-Filters, or Charcoal positioning of each Filter and •...
  • Page 55: Parts List

    Please visit our website at: www.gfse.com or e-mail services@gfse.com. The goal of the Giles team is to provide you with the highest quality service and assistance. You can help us accomplish this by obtaining the following information and having it readily available when calling. The information is recorded on a Serial Plate or Label attached to the unit.
  • Page 56: Component Drawer & Control Panel

    Model: FSH-5 & FSH-6 Parts List 7-2. Component Drawer & Control Panel...
  • Page 57 Parts List Model: FSH-5 & FSH-6 7-2. Parts List for Component Drawer & Control Panel Item Part No. Qty. Description 21296 EAC POWER SUPPLY, w/DRIVER BOARD, 120V 23776 ALARM & SHUTDOWN MODULE, AIR FILTER 23751 TERMINAL BLOCK, MA106 22300 INDICATOR LIGHT, RED, 250V, ROUND...
  • Page 58: Front View -Doors And Panel Removed

    Model: FSH-5 & FSH-6 Parts List 7-3. Front View - Filter Chambers (Doors & Duct Panel Removed) * Not Shown...
  • Page 59 Parts List Model: FSH-5 & FSH-6 7-3. Parts List for Front View - Filter Chambers (Doors & Duct Panel Removed) Item Part No. Qty. Description 91707 PRE-FILTER, ASSEMBLY, 12 X 20 X 2 31843 DRIP PAN, E.A.C. FILTER 20521 FILTER, EAC 12 X 20, LEFT SIDE ONLY...
  • Page 60: Baffle Filters And Switches

    Model: FSH-5 & FSH-6 Parts List 7-4. Baffle Filters & Switches...
  • Page 61 Parts List Model: FSH-5 & FSH-6 7-4. Parts List for Baffle Filters & Switches Item Part No. Qty. Description 42300 FILTER, BAFFLE, S/S, 20 X 20 32776 DRIP CUP 32102 BAFFLE FILTER SWITCH ASSEMBLY...
  • Page 62: Doors And Front Panel

    Model: FSH-5 & FSH-6 Parts List 7-5. Doors & Front Panel (Ceiling Mounted) * Not Shown...
  • Page 63 FIRE DAMPER 33205 FAN DUCT PANEL ASSEMBLY 43053 GUARD, FIRE DAMPER 33253 FILTER DOOR ASSEMBLY, RIGHT 32026 HOOD SKIRT, 8”, CEILING MOUNT, FSH-5 34231 HOOD SKIRT, 8”, CEILING MOUNT, FSH-6 31867 SIDE-SKIRT PANEL, LEFT 31868 SIDE-SKIRT PANEL, RIGHT 31885 BACK-SPLASH PANEL, FSH-5...
  • Page 64: Stand Mount Skirts

    Model: FSH-5 & FSH-6 Parts List 7-6. Stand Mounted Hood * Not Shown...
  • Page 65 91938 91947 72” BOTTOM BACK PANEL, FSH-5 91940 72” BOTTOM BACK PANEL, FSH-6 92062 APPLIANCE POSITIONING CHANNEL, FSH-5 92063 APPLIANCE POSITIONING CHANNEL, FSH-6 HOOD SKIRT, 8”, STAND MOUNT, FSH-5 91950 91945 HOOD SKIRT, 8”, STAND MOUNT, FSH-6 * Not Shown...
  • Page 66 Model: FSH-5 & FSH-6 Parts List Notes:...
  • Page 67 Model: FSH-5 & FSH-6...
  • Page 68 Giles Foodservice Equipment 2750 Gunter Park Drive West • Montgomery, Al 36109 USA Phone 334.272.1457 • Toll Free 800.554.4537 (USA & Canada) • FAX 334.239-4117 • www.gfse.com Form No. 64898 (Rel. Date: 07/1999, Rev. Date: 04/2015; Rev. G)

This manual is also suitable for:

Fsh-6

Table of Contents