GILES OVH-10-FB Operation & Service Manual

Ventless hood

Advertisement

Quick Links

Operations & Service Manual
Model OVH-11-FB
with Removeable
Front Side Skirts
Giles Enterprises, Inc.
ISO 9001-2008 Registered Company • Committed to Quality
2750 Gunter Park Drive West • Montgomery, AL 36109 USA
Phone: 334.272.1457 • Fax: 334.239.4117 • www.gfse.com
Toll Free: 800.554.4537 (
USA & Canada Only
OVH-10-FB
OVH-11-FB
)
Form 65873.B (Rel. Jun 2013; Rev.B Aug 2016)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OVH-10-FB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GILES OVH-10-FB

  • Page 1 OVH-11-FB Model OVH-11-FB with Removeable Front Side Skirts Giles Enterprises, Inc. ISO 9001-2008 Registered Company • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Phone: 334.272.1457 • Fax: 334.239.4117 • www.gfse.com Toll Free: 800.554.4537 ( USA &...
  • Page 3 Failure to use Giles OEM parts and Giles OEM replacement Filters may void the Warranty. • Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured.
  • Page 5: Table Of Contents

    Table Of Contents Model: OVH-10-FB & 11-FB Safety ............v Safety Overview .
  • Page 6 Rear Electrical Components: OVH-10-FB ........
  • Page 7: Safety

    The instructions contained in this manual have been prepared to aid in learning the proper procedures for installing operating and servicing the OVH-10-FB or OVH-11-FB Ventless Hood. Throughout this manual, safety precautions are identified through the use of safety alert symbols and key words such as DANGER, WARNING and CAUTION.
  • Page 8: Specific Safety Precautions

    Model: OVH-10-FB & 11-FB Safety Specific Safety Precautions For your safety, please observe the following precautions when operating or servicing the OVH-10/11-FB Ventless Hood. Read the following important safety information to avoid personal injury and/or damage to the equipment or property.
  • Page 9 • Comply with all appropriate state and/or local heath regulations regarding cleaning and sanitation of foodservice equipment. • Giles recommends the use of mild, bio-degradable, non-toxic degreasers, such as Clear Magic or Simple Green, for cleaning parts of the hood where excessive grease film accumulation is present.
  • Page 10 Model: OVH-10-FB; OVH-11-FB Safety viii...
  • Page 11: Introduction

    Introduction Model: OVH-10-FB & 11-FB Introduction Thank You for purchasing the OVH-10-FB or OVH-11-FB Ventless Recirculating Hood manufactured by Giles Foodservice Equipment. These are Limited Type-1 Hoods designed for pairing with specific appliances, such as the Cleveland Convotherm 6.10 Oven.
  • Page 12: Specifications

    Model: OVH-10-FB; OVH-11-FB Introduction 1-04. Specifications 1-04.1. Overall Dimensions Dimension OVH-10-FB OVH-11-FB 39-7/8 [1012.8] 42-3/16 [1071.5] 30-5/16 [769.9] 34-13/16 [844.4] Inches [mm]...
  • Page 13: Regulatory Listings

    Introduction Model: OVH-10-FB & 11-FB 1-04.2. Regulatory Listings 1-04.3. Hood Weight Hood Crated Weight Uncrated Weight OVH-10-FB 221 lbs [100.2 kg] 130 lbs [58.9 kg] OVH-11-FB 235 lbs [106.6 kg] 165 lbs [74.8 kg]...
  • Page 14: Installation

    Model: OVH-10-FB & 11-FB Installation Installation This section summarizes the procedures necessary to install the OVH-10-FB or OVH-11-FB Hood. Before installing and attempting to operate, please read the contents of this manual thoroughly. Following these procedures will help ensure safe and proper installation.
  • Page 15: Location

    • Exhaust ventilation is recommended for areas in which recirculating hoods are operated. Giles recommends 50 CFM per linear foot of hood space. This could vary based on local codes and site-specific situations.
  • Page 16: 2-02.1 Clearance To Combustibles

    Model: OVH-10-FB & 11-FB Installation 2-02.1 Clearance to Combustibles Dimension OVH-10-FB OVH-11-FB 39-7/8 [1012.8] 42-3/16 [1071.5] 30-5/16 [769.9] 34-13/16 [844.4]...
  • Page 17: Cooking Appliance Limitations & Clearances

    Installation Model: OVH-10-FB & 11-FB 2-03. Cooking Appliance Limitations & Clearances Hood is listed for Electric Appliances ONLY. Dimension OVH-10-FB OVH-11-FB APPLIANCE RESTRICTIONS 39-7/8 [1012.8] 42-3/16 [1071.5] (A) MAX APPLIANCE TYPE MAX. ELECTRIC INPUT kW (WATTS) INCH (mm) 30-5/16 [769.9] 34-13/16 [844.4]...
  • Page 18: Electrical Requirements

    Model: OVH-10-FB & 11-FB Installation 2-04. Electrical Requirements WARNING • Consult a qualified electrician to ensure that all electrical specifications have been met and that the unit is properly grounded. • Improper installation, adjustment, alteration, service or maintenance could result in serious injury or even death, damage to equipment or property, and void the warranty.
  • Page 19: 2-04.1. Electrical Connections

    4. Connect Hood and Appliance wiring to Hood terminal blocks. Adhere to all local electrical code. Several different wiring configuration options are possible depending on specific installation situations. See Section 2-04.2 for specific details of these options. If you have questions call Giles Technical Services (800.554.4537) for assistance.
  • Page 20: 2-04.2. Hood & Appliance Wiring Configurations

    Model: OVH-10-FB & 11-FB Installation 2-04.2. Hood & Appliance Wiring Configurations...
  • Page 21: Installation With Plug & Receptacle Option

    Installation Model: OVH-10-FB & 11-FB 2-04.3. Installation with Plug & Receptacle Option Appliance Power Receptacle Hood Power Cord The following applies only if the Hood is equipped with the Plug & Receptacle Option: 1. Uncoil the Hood power cord located on the rear of unit.
  • Page 22 Model: OVH-10-FB & 11-FB Overview...
  • Page 23: Overview

    Model: OVH-10-FB & 11-FB Overview The following section provides a brief overview of the components, functions, and accessories of the OVH-10-FB/OVH-11-FB Ventless Hood. Please review this section carefully before attempting to operate the unit. Hood Exhaust Air Diverter Filter Access...
  • Page 24: Control Panel

    Model: OVH-10-FB, OVH-11-FB Overview 3-01. Control Panel ILS Only; Not Shown...
  • Page 25 Overview Model: Model: OVH-10-FB & 11-FB 3-01. Control Panel Item Description Function The Power Switch is a two-position Switch. Placing switch in the ON Power Switch position starts the hood fan. After placing Power Switch in the ON position, push and hold PUSH TO START button for approx.
  • Page 26: Hood Front & Filter Chamber

    Model: OVH-10-FB Overview 3-02. Hood Front & Filter Chamber...
  • Page 27 Overview Model: OVH-10-FB & 11-FB 3-02. Hood Front & Filter Chamber Item Description Function Provides access to the filter chamber and plenum area of the Filter Access Door Hood. This door must be in place and secure before the unit will turn ON.
  • Page 28: Accessories (Standard)

    Model: OVH-10-FB; OVH-11-FB Overview 3-03. Accessories (Standard) Part Description/Part Number Function Captures large grease particulate, Baffle Filter P/N 45096 removing it from the airstream. EAC Filter Cell Electrostatically removes fine P/N 22360 grease particulate from the airstream. Charcoal Fiber Filter...
  • Page 29 Overview Model: OVH-10-FB & 11-FB 3-03. Accessories (Standard) Part Description/Part Number Function EAC Soak Tank Used for soaking and cleaning the P/N 39327 EAC Filter Cell.
  • Page 30 Model: OVH-10-FB; OVH-11-FB Overview NOTES:...
  • Page 31: Operation & Filter Maintenance

    Operation & Filter Maintenance Model: OVH-10-FB & 11-FB Operation & Filter Maintenance The following section describes Hood operation, Filter maintenance, and other general care activities. 4-01. Hood Operation Confirm that all Filters are in place and properly seated before attempting to operate the hood. The Filter Access Door must be in place and secure.
  • Page 32: Hood Filter System

    Operation & Filter Maintenance 4-02. Hood Filter System The OVH-10-FB and OVH-11-FB Hood Filter System consist of three (3) stages. The following section describes filter maintenance and cleaning procedures necessary to keep the air cleaning system operating at peak performance. 4-02.1.
  • Page 33: 4-02.2. Filter Removal, Baffle, Eac, Charcoal

    Operation & Filter Maintenance Model: OVH-10-FB & 11-FB 4-02.2. Filter Removal - Baffle, EAC Cell & Charcoal 1. Place Power Switch in OFF position. 2. Remove Filter Access Door ... Grasp Handle, lift and slide Door straight up so that bottom edge will clear flange.
  • Page 34: 4-02.3. Filter Installation, Baffle, Eac, Charcoal

    Model: OVH-10-FB & 11-FB Operation & Filter Maintenance 4-02.3. Filter Installation - Baffle, EAC Cell & Charcoal To reinstall Filters, align it with the filter channel and slide straight into Hood until filter hits a stop. Note airflow direction arrows on filters when reinstalling.
  • Page 35: Eac Filter Status

    Operation & Filter Maintenance Model: OVH-10-FB & 11-FB 4-02.6. EAC Filter Status Three small yellow indicator lights on the Control Panel display the status of the EAC Filter System. Light is ON to indicate the EAC Filter Cell is in place, powered and operating properly to clean the airstream through the Hood.
  • Page 36: 4-03.2. Eac Filter Cleaning

    Charcoal Filter will require replacement between 30 and 90 days. Replacement Part No. 94486. It is advised that the installation date be recorded in the space provided on the new filter label. Failure to use Giles OEM parts and OEM replacement Filters may void the factory warranty.
  • Page 37: Filter Alarm Chart

    Operation & Filter Maintenance Model: OVH-10-FB & 11-FB 4-04. Filter Alarm Chart Alarm Sound What will happen Filter Cause Solution Section Alarm sounds, Charcoal or Baffle Filter dirty Filter Clogged lamp illuminates, and Replace 4-02.2 & Continuous tone power to the appliance is shutdown.
  • Page 38 Model: OVH-10-FB & 11-FB Operation & Filter Maintenance NOTES:...
  • Page 39: Hood Cleaning And Maintenance

    Hood Cleaning & Maintenance Model: OVH-10-FB & 11-FB Hood Cleaning & Maintenance The following section describes the activities generally needed to maintain and clean the OVH-10/11-FB Hood. Attention to these procedures will help ensure that the Hood remains in good condition and continues to run efficiently and safely.
  • Page 40: Hood Cleaning

    Model: OVH-10-FB & 11-FB Hood Cleaning & Maintenance 5-02. Hood Cleaning C UTION ● ● DO NOT steam clean or use any type pressure washer. DO NOT wash down hood with water from a spray hose. ● DO NOT use products containing chlorine, or other caustic chemicals.
  • Page 41: Maintenance And Service Log

    Hood Cleaning & Maintenance Model: OVH-10-FB & 11-FB 5-03. Maintenance & Service Log Check Initial/Date Check Initial/Date BC 1/31/12 1 Door Check Section 5-01. 2 Baffle Filter Check Section 5-01. 3 EAC Filter Check Section 5-01. 4 Charcoal Filter Check Section 5-01.
  • Page 42 Model: OVH-10-FB & 11-FB Hood Cleaning & Maintenance Notes:...
  • Page 43: Troubleshooting

    Troubleshooting Model: OVH-10 & 11-FB Trouble Shooting he following section describes basic troubleshooting procedures for the OV H - 10 & 11- F B H o o d . The wiring diagram provided with the unit is to assist qualified technicians with more in-depth troubleshooting. DANGER •...
  • Page 44 Model: OVH-10 & 11-FB Troubleshooting 6-01. Troubleshooting Procedures (Continued) Problem Probable Cause Corrective Action Cooking appliance will not operate ... a. Baffle Filter missing or not Install Baffle Filter or check alignment. • Hood Powered light ON properly installed • FILTER MISSING light ON b.
  • Page 45: Parts List

    Visit our website at: www.gfse.com or e-mail services@gfse.com. The goal of the Giles team is to provide you with the highest quality service and assistance possible. To help us accomplish this please have the following information readily available when calling, along with the nature of the problem you are encountering.
  • Page 46: Rear Electrical Components: Ovh-10-Fb

    Model: OVH-10-FB & 11-FB Parts List 7-02. Rear Electrical Components: OVH-10-FB REAR PANEL ILS Model Only # Not Seen SIDE PANEL...
  • Page 47 Parts List Model: OVH-10-FB & 11-FB 7-02. Parts List for Rear Components: OVH-10-FB Item Part No. Qty. Description 35881 FAN ASSY, OVH-10, 208-240/60/1 24208 EAC POWER SUPPLY & DRIVER BOARD, 208-240V 23776 AIR FILTER ALARM & SHUTDOWN MODULE 21337 TRANSFORMER, 230VAC to 115VAC @.86A, TRIAD 20473 VACUUM SWITCH, DUNGS, 0.4 >...
  • Page 48: Rear Electrical Components: Ovh-11-Fb

    Model: OVH-10-FB & 11-FB Parts List 7-03. Rear Electrical Components: OVH-11-FB REAR PANEL ILS Model Only # Not Seen SIDE PANEL...
  • Page 49 Parts List Model: OVH-10-FB & 11-FB 7-03. Parts List for Rear Components: OVH-11-FB Item Part No. Qty. Description 35864 FAN ASSEMBLY, 208-240/60/1 24208 EAC POWER SUPPLY & DRIVER BOARD, 208-240V 23751 TERMINAL BLOCK, MA106 23776 AIR FILTER ALARM & SHUTDOWN MODULE 21337 TRANSFORMER, 230VAC to 115VAC @.86A, TRIAD...
  • Page 50: Hood Front & Filter Compartment

    Model: OVH-10-FB & 11-FB Parts List 7-04. Hood Front & Filter Compartment ILS Model Only...
  • Page 51 Parts List Model: OVH-10-FB & 11-FB 7-04. Parts List for Hood Front & Filter Compartment Item Part No. Qty. Description 92399 FILTER ACCESS DOOR 42825 HANDLE 31963 CHARCOAL FILTER ASSY, 16 X 12-3/8 X 2 22360 E.A.C. FILTER, 16” 45096...
  • Page 52 Model: OVH-10-FB & 11-FB Parts List NOTES:...
  • Page 54 Giles Enterprises, Inc. 2750 Gunter Park Drive West • Montgomery, Al 36109 USA Phone 334.272.1457 • Toll Free 800.554.4537 (USA & Canada Only) • FAX 334.239.4117 • www.gfse.com Form No. 65873.B (Rel. Jun 2013; Rev.B Aug 2016)

This manual is also suitable for:

Ovh-11-fb

Table of Contents